Determination of Quercetin and Luteolin in Paprika Samples by Voltammetry and Partial Least Squares Calibration

Abstract: Quercetin and luteolin are flavonoids with beneficious properties, which are present in paprika. In this work, both have been determined in paprika by using electrochemistry combined with chemometrics. The electrochemical oxidation mechanisms of both analytes have been studied through sampled direct current (DC) voltammetry, differential pulse voltammetry (DPV) and Square Wave Voltammetry (SWV), making use of a glassy carbon electrode. The final technique selected for the quantification was DPV due to its high… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…At this point, it is important to highlight the work carried out by the group of Galeano-Díaz in which by moving the focus to data analysis instead of the electrode modification, they get good results (even in selectivity) through the use of a bare GCE together with a data analysis based on partial least squares analysis (PLS). 91 Probably in the case of luteolin determination in real samples, it is more important that the sensor has a wider linear range than that it has an extremely low LOD. In a sample with an unknown value of luteolin concentration, it is important that the measured value falls within the calibration curve to avoid errors.…”
Section: Electrochemical Determinationsmentioning
confidence: 99%
See 1 more Smart Citation
“…At this point, it is important to highlight the work carried out by the group of Galeano-Díaz in which by moving the focus to data analysis instead of the electrode modification, they get good results (even in selectivity) through the use of a bare GCE together with a data analysis based on partial least squares analysis (PLS). 91 Probably in the case of luteolin determination in real samples, it is more important that the sensor has a wider linear range than that it has an extremely low LOD. In a sample with an unknown value of luteolin concentration, it is important that the measured value falls within the calibration curve to avoid errors.…”
Section: Electrochemical Determinationsmentioning
confidence: 99%
“…Finally, an item that involves cost, portability, and stability is the simplicity of the electrode and/or the method used. At this point, it is important to highlight the work carried out by the group of Galeano‐Díaz in which by moving the focus to data analysis instead of the electrode modification, they get good results (even in selectivity) through the use of a bare GCE together with a data analysis based on partial least squares analysis (PLS) 91 …”
Section: Electrochemical Determinationsmentioning
confidence: 99%
“…In the literature, individual or simultaneously determination of these molecules were carried out after some modification procedure or different calculation method (Table 2). 16,18,20,21,[24][25][26] In this study, the simultaneous determination of Qu and Lu was performed with high sensitivity and wide linear ranges using the unmodified GCE and calibration curve.…”
Section: Analytical Applicationmentioning
confidence: 99%
“…In the literature, there was only one study about the simultaneous electrochemical determination of Qu and Lu. 26 Chamizo-Gonzalez, Monago-Marana and Galeano-Diaz (2017) reported DPV and partial least squares.…”
Section: Introduction *mentioning
confidence: 99%