2011
DOI: 10.1007/978-3-642-21729-6_108
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Reflectance Optical Sensor Array Configuration Using 3-Layer Tissue Model and Monte Carlo Simulation

Abstract: A new reflectance optical sensor array for locating fetal signal transabdominally has been determined in this study. The selection of optical sensor array is based on the highest Irradiance (μW/m 2 ) value estimated on respected detectors. A three-layer semi-infinite tissue model which consists of maternal, amniotic fluid sac and fetal tissues is employed to study the optical sensor array configuration. By using statistical error approach, the number of rays injected to the system can be set to 1 million rays … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2012
2012
2014
2014

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…To make each layer become meanin simulation, optical properties at 890nm [8] each layer using smartIGES™ translatio optical properties are the refractive index reduced scattering coefficient, and anisotrop…”
Section: Optical Softwarementioning
confidence: 99%
See 2 more Smart Citations
“…To make each layer become meanin simulation, optical properties at 890nm [8] each layer using smartIGES™ translatio optical properties are the refractive index reduced scattering coefficient, and anisotrop…”
Section: Optical Softwarementioning
confidence: 99%
“…These , absorption and py factor. sources in ASAP om rays or using an Infrared Light 890nm is used to R command, the aphical intensity ur detectors are onfiguration [8]. and is positioned .…”
Section: Complete Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…To avoid such invasive interference, a transabdominal fetal pulse oximetry system has been introduced [2]- [5]. Regarding the transabdominal fetal pulse oximetry, there are several studies that have been conducted to maximize the output received by the fetal detectors such as case studies involving the determination of the suitable emitterdetector spacing [6], the arrangement of optical array for fetal reflectance probes [7] as well as the best selection for wavelength pairs to be applied as the light source in the fetus pulse oximetry system [2], [8].…”
Section: Introductionmentioning
confidence: 99%