2016
DOI: 10.1007/s12161-016-0664-6
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Rice Storage Time with Colorimetric Sensor Array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 42 publications
(15 citation statements)
references
References 24 publications
0
15
0
Order By: Relevance
“…(c) Each solution was printed on the silica gel plates using 0.1 μL microcapillary pipettes. (d) The arrays dried for 30 min in a fume hood, and then kept in a glove bag that was previously flushed with nitrogen gas (Chen et al, ; Guan, Zhao, Jin, & Lin, ; Huang, Lv, Wang, Aheto, & Dai, ).…”
Section: Methodsmentioning
confidence: 99%
“…(c) Each solution was printed on the silica gel plates using 0.1 μL microcapillary pipettes. (d) The arrays dried for 30 min in a fume hood, and then kept in a glove bag that was previously flushed with nitrogen gas (Chen et al, ; Guan, Zhao, Jin, & Lin, ; Huang, Lv, Wang, Aheto, & Dai, ).…”
Section: Methodsmentioning
confidence: 99%
“…The result shows that, with using the new designed chamber, obtained from COMSOL Multiphysics analysis, the volatile organic compounds may adequately exposed to each colorimetric dye of the sensors. Consequently, a shorter time and lower requirement of experiment, comparing to twice experiment times and higher temperature (80 C) is required in the literature (Guan et al, 2017), and a better performance, with the identification rate of 100%, was achieved.…”
Section: Classification Results Of New Rice and Aged Ricementioning
confidence: 99%
“…The CSA was made as based on the method proposed by (Guan et al, ): (1) porphyrins were dissolved in methylene chloride, and the pH indicators were dissolved in ethanol; (2) colorimetric dye solutions of 2 mg/mL were obtained after ultrasound for 1 hr; (3) colorimetric dyes were printed on the hydrophobic polyvinylidene fluoride (PVDF) membrane (Merck Millipore, Germany) using microcapillary pipettes, constructing a 3 × 3 sensor array; (4) after 15 min drying in the fume hood, the CSA were maintained in a closed environment for further process.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For images of before and after response from the same CSA, RGB (red, green, and blue) values model was performed to obtain the difference value so as to get the total number of variables of 12 (4dot (labeled S1, S2, S3, and S4) ×∆R, ∆G, ∆B value). The value obtained was used as the original data for pattern recognition and analysis [ 22 , 23 ]. For classification, PCA and LDA were used to distinguish vinegar of different storage time [ 24 ].…”
Section: Methodsmentioning
confidence: 99%