Determination of Salbutamol in Human Plasma and Urine by High-Performance Liquid Chromatography with a Coulometric Electrode Array System

Abstract: A method is developed to determine salbutamol in human plasma and urine using high-performance liquid chromatography (HPLC) with a coulometric electrode array system, based on the electrochemical behavior of salbutamol at graphite electrode. The mobile phase component A is 30 mM sodium dihydroxy phosphate-30 mM triethylamine and is adjusted to pH 6.0 with 20% phosphate acid. The mobile phase component B is methanol. The optimized mobile phase composition was A and B in the proportion of 90:10 (v/v). Paracetamo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…The SPE using the Sep-Pak Silica column is used as a pretreatment of samples. The recovery of this method reached about 77.32% and 81.25% [ 53 ]. Compared with the recovery results in this study, MIPMS-SPE can increase the value of % recovery of salbutamol compared to conventional SPE.…”
Section: Application Of the Spe Sorbent To Extract Salbutamol From Sp...mentioning
confidence: 99%
“…The SPE using the Sep-Pak Silica column is used as a pretreatment of samples. The recovery of this method reached about 77.32% and 81.25% [ 53 ]. Compared with the recovery results in this study, MIPMS-SPE can increase the value of % recovery of salbutamol compared to conventional SPE.…”
Section: Application Of the Spe Sorbent To Extract Salbutamol From Sp...mentioning
confidence: 99%
“…Tables 7.2 and 7.3 show the LC-EC and FIA-EC with their hyphenated EC-MS detection systems used in the methods, respectively. Plasma sample [74] (continued) Cerebrospinal fluid [83] (continued) (continued) [107] (continued) Bovine and human serum samples [118] (continued) 7.5 Hyphenated Techniques for LC and FIA Phyto-pharmaceutical formulations [130] (continued) Plasma and urine samples [144] (continued) …”
Section: Hyphenated Techniques For Lc and Fiamentioning
confidence: 99%
“…4,5 Nevertheless, there is no literary research in this field of estimating and separating SBS using ZIC-hydrophilic (ZIC-HILIC) techniques, despite a number of studies for the separation and determination of SBS in High-performance RESEARCH ARTICLE liquid chromatography (HPLC). [6][7][8][9] In addition, the effect of the ZIC-HILIC column's chain longitude on SBS retention behavior was not previously studied. In a recent study, Rasheed and coworkers [10][11][12] studied the effect of chain length on HILIC columns and its effect on ranitidine and famotidine behaviors.…”
Section: Introductionmentioning
confidence: 99%