2013
DOI: 10.1002/elps.201200267
|View full text |Cite
|
Sign up to set email alerts
|

Determination of UV filters in river water samples by in‐line SPECEMS

Abstract: The use of SPE coupled in-line to CE using electrospray MS detection (in-line SPE-CE-ESI-MS) was investigated for the preconcentration and separation of four UV filters: benzophenone-3, 2,2-dihydroxy-4-methoxybenzophenone, 2,4-dihydroxybenzophenone and 2-phenylbenzimidazole-5-sulphonic acid. First, a CE-ESI-MS method was developed and validated using standard samples, obtaining LODs between 0.06 μg/mL and 0.40 μg/mL. For the in-line SPE-CE-ESI-MS method, three different sorbents were evaluated and compared: Oa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
3
3
2

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 51 publications
0
20
1
Order By: Relevance
“…Classical C18 [23,58,79] and polymeric PS-DVB [54,73] . When compounds with acidic properties (e.g., benzophenone-4 (BZ4) and phenylbenzymidazole sulfonic acid (PBS)) are also pursued, PVP-DVB/MCX shows better performance compared to PVP-DVB [28,70], since the non-acidic compounds are well retained in the PVP-DVB skeleton, whereas the acidic ones prefer the modified moieties.…”
Section: Uv Filtersmentioning
confidence: 99%
See 2 more Smart Citations
“…Classical C18 [23,58,79] and polymeric PS-DVB [54,73] . When compounds with acidic properties (e.g., benzophenone-4 (BZ4) and phenylbenzymidazole sulfonic acid (PBS)) are also pursued, PVP-DVB/MCX shows better performance compared to PVP-DVB [28,70], since the non-acidic compounds are well retained in the PVP-DVB skeleton, whereas the acidic ones prefer the modified moieties.…”
Section: Uv Filtersmentioning
confidence: 99%
“…Oliveira et al used a multisyringe-lab-on-valve approach [46] and GagoFerrero et al employed a commercial on-line SPE device [73], in both cases coupled to LC. Maijó et al performed SPE in-line coupled to capillary electrophoresis (CE) by inserting the SPE sorbent between two pieces of the capillary [70].…”
Section: Uv Filtersmentioning
confidence: 99%
See 1 more Smart Citation
“…In in‐line SPE‐CE, an analyte concentrator is synthesized or placed as a short column near the inlet end of the CE capillary . To do so, different set‐ups have been reported in the literature, of which the most commonly used is the system based on the use of small packed beads, with the most widely employed sorbents being Oasis HLB, Oasis MCX, and C 18 . In this configuration, the SPE material can be retained by means of two frits but, over time, their use has become less advisable due to issues with performance arising from several disadvantages discussed elsewhere .…”
Section: Introductionmentioning
confidence: 99%
“…ESI is the ionization source of choice when LC–MS/MS multiclass methods for the determination of personal care products and pharmaceuticals in aquatic environment are proposed . CE–ESI‐MS has also been used for UV filter determination in river water .…”
Section: Introductionmentioning
confidence: 99%