1980
DOI: 10.1021/ac50054a037
|View full text |Cite
|
Sign up to set email alerts
|

Determination of selenium in environmental standard reference materials by a .gamma.-.gamma. coincidence method using lithium-drifted germanium detectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

1983
1983
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…For this reason, the use of coincidence has been demonstrated to significantly reduce background counts [5]. The use of gamma-gamma coincidence produces a count reduction of 3 to 4 magnitudes when measuring selenium ( 75 Se) in environmental standards using neutron activation analysis [6]. Gamma-gamma * cegozi@utexas.edu coincidence counting allows for lower detection limits, particularly in conjunction with the use of energy gating.…”
Section: Introductionmentioning
confidence: 99%
“…For this reason, the use of coincidence has been demonstrated to significantly reduce background counts [5]. The use of gamma-gamma coincidence produces a count reduction of 3 to 4 magnitudes when measuring selenium ( 75 Se) in environmental standards using neutron activation analysis [6]. Gamma-gamma * cegozi@utexas.edu coincidence counting allows for lower detection limits, particularly in conjunction with the use of energy gating.…”
Section: Introductionmentioning
confidence: 99%
“…The gamma-gamma coincidence method is mainly applied for experimental studies of the nuclear structure. Thanks to its ability to reduce the gamma rays background and the selection of events correlation in timing, these methods have been used for NAA [2][3][4][5]. Lawrence E. Wangen et al have used a coincidence method using Ge(Li) Detectors to evaluate Se detection limits and background reductions for Normal and Coincidence counting procedures [2].…”
Section: Introductionmentioning
confidence: 99%
“…Many analyses have been performed on NBS coal and ash standards to demonstrate the applicability of INAA to the analysis of these types of samples (59)(60)(61)(62)(63)(64)(65)(66)(67)(68)(69)(70)(71)(72)(73)(74). Differences in matrix between samples and standards are not important because only the nuclear properties of the elements are involved in the analyses (60).…”
Section: Photographic Detectionmentioning
confidence: 99%
“…Differences in matrix between samples and standards are not important because only the nuclear properties of the elements are involved in the analyses (60). The coincidence of gamma-rays emitted by certain elements and their measurement by dual detectors has been used to improve the sensitivity of the method for some elements (65 Fluorimetric methods have been used for the analysis of selenium (80) and uranium (161-163). Precisions and accuracies are generally as good as or better than ±10%.…”
Section: Photographic Detectionmentioning
confidence: 99%