2013
DOI: 10.1016/j.aca.2013.01.051
|View full text |Cite
|
Sign up to set email alerts
|

Determination of selenium using atomically imprinted polymer (AIP) and hydride generation atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 53 publications
0
9
0
Order By: Relevance
“…An atomically imprinted polymer synthesised from SeO 2 , 4-vinylpyridine and vinylimidazole was used in a minicolumn (5.4 cm  2.1 cm) for the preconcentration and determination of Se using FI-HG-FAAS. 23 An LOD of 53 ng L À1 was obtained which the authors claim to be the best currently reported. Interferents such as Cu 2+ and Cr 3+ were noted and therefore analysis by standard additions was recommended in their presence.…”
Section: Rare Earth Elementsmentioning
confidence: 86%
See 2 more Smart Citations
“…An atomically imprinted polymer synthesised from SeO 2 , 4-vinylpyridine and vinylimidazole was used in a minicolumn (5.4 cm  2.1 cm) for the preconcentration and determination of Se using FI-HG-FAAS. 23 An LOD of 53 ng L À1 was obtained which the authors claim to be the best currently reported. Interferents such as Cu 2+ and Cr 3+ were noted and therefore analysis by standard additions was recommended in their presence.…”
Section: Rare Earth Elementsmentioning
confidence: 86%
“…A second novel pre-concentration method for determination of Se was reported by de Lima et al 23 The pre-concentration medium was described as an atomically imprinted polymer (AIP), a development from molecularly-and ion-imprinted polymers, which are synthetic materials with recesses specically prepared to retain a molecule, ion or atom of interest. The polymer was prepared from 4 vinylpyridine, 1-vinylimidazole, ethylene glycol dimethacrylate and 2,2 0 -azobis-isobutyronitrile.…”
Section: Digestion Extraction and Pre-concentrationmentioning
confidence: 99%
See 1 more Smart Citation
“…They achieved an LOD of <0.2 ng mL À1 using FAAS and selectivity of preconcentration in the presence of palladium and platinum. Another novel IIP has been reported by de Lima et al 12 who formed the polymer by reduction of Se IV to Se 0 prior to reaction with 4-vinylpyridine and vinylimidazole, hence they designated the product as an atom imprinted polymer (AIP). Preconcentration of Se was achieved in FI mode by rst reducing the analyte to Se 0 , using 0.5% (w/v) citric acid, then preconcentration on the AIP which was immobilised in a mini-column.…”
Section: Liquidsmentioning
confidence: 99%
“…Different instrumental methods including UV-vis spectrophotometry, 3,4 kinetic spectrophotometry, 5,6 optical emission spectrometry (OES) 7 and atomic absorption spectrometry (AAS) 8,9 are prevalently used for selenium determination.…”
Section: Introductionmentioning
confidence: 99%