2014
DOI: 10.4236/pp.2014.52026
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Seven Volatile N-Nitrosamines in Fast Food

Abstract: In this study, various fast food samples, including raw meat, cured meat, grilled meat, fried meat, smoked meat and canned meat products, were analyzed for the determination of the seven volatile N-nitrosamines. The samples were treated with an aqueous sodium hydroxide (NaOH) by autoclaving at 121˚C for 10 min and extracted by liquid-liquid extraction with dichloromethane, and then the nitrosamines were pre-concentrated by using activated silica. Then, gas chromatography coupled with flame ionization detector … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 32 publications
0
8
0
Order By: Relevance
“…Al‐Kaseem et al. (2014)evaluated various types of meat(raw, cured, grilled, fried, smoked, and canned meat products) to detect and measure N‐nitrosamines (NDMA, NDEA, NDPA, NDBA, NPYR, and NPIP). Their results indicated no significant difference in the quantity of various nitrosamines in the raw meat samples, but the amount of these compounds was significantly changed by application of thermal treatments.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Al‐Kaseem et al. (2014)evaluated various types of meat(raw, cured, grilled, fried, smoked, and canned meat products) to detect and measure N‐nitrosamines (NDMA, NDEA, NDPA, NDBA, NPYR, and NPIP). Their results indicated no significant difference in the quantity of various nitrosamines in the raw meat samples, but the amount of these compounds was significantly changed by application of thermal treatments.…”
Section: Resultsmentioning
confidence: 99%
“…After adding 100 µl octane to the drying hamper solvent, the eluate solutions were concentrated by a K‐D concentrator using nitrogen gas flow to 1 ml. Finally, 1‐µl standard solution was injected by GC‐FID (Al‐Kaseem et al., 2014).…”
Section: Methodsmentioning
confidence: 99%
“…The nitrogen generator was turned on until it is ready to produce nitrogen gas used for mass spectrometry detectors. Then high performance liquid chromatography (Agilent 1290 HPLC) mass spectrometry (ABSciex API 4000 Q TRAP type) was turned on, by: turning on the mass spectrometry detector, setting positive detection, leaving it for a while until the mass spectrometry conditions become vacuum, run the pump on the type mixture of mobile phase, comparison of ratio mobile phase and predetermined mobile phase flow rate, as well as column oven temperature set at predetermined conditions, then the mobile phase was flowed until a stable pressure was obtained, which indicates that the high-performance liquid chromatography system of mass spectrometry has been stable and ready used for analysis [14].…”
Section: Methodsmentioning
confidence: 99%
“…Nitrosamine analysis in food can be done by high-performance liquid chromatography and gas chromatography with a detector system. The method of high-performance liquid chromatography using mass spectroscopy is very selective and sensitive and can be used as an alternative method compared to other chromatographic methods [12], [13], [14], [15], [16].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, nitrosamines have also been discussed in public because of their easy formation in food, such as fast food 10 or barbecue meals, 11 or in rubber products, such as condoms 12 . All these factors place urgency to solve and improve the nitrosamine impurity quantification methods in an accurate manner.…”
Section: Introductionmentioning
confidence: 99%