1984
DOI: 10.1016/s0378-4347(00)83351-4
|View full text |Cite
|
Sign up to set email alerts
|

Determination of sisomicin, netilmicin, astromicin and micronomicin in serum by high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
12
0

Year Published

1985
1985
2012
2012

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 5 publications
0
12
0
Order By: Relevance
“…Several methods have been described to determine netilmicin in pharmaceutical formulations and biological matrices. Precolumn derivatization LC with dansyl chloride 10, o ‐phthalaldehyde (OPA) 11–14, 1‐fluoro‐2,4‐dinitrobenzene 15, 16, 11‐fluorenylmethyl chloroformate 17, or OPA‐β‐mercaptopropionic acid 18, 19, and postcolumn LC derivatization with OPA 20, 21 combined with fluorescence or UV detection have been described. However, these techniques are time consuming and give problems in quantification.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been described to determine netilmicin in pharmaceutical formulations and biological matrices. Precolumn derivatization LC with dansyl chloride 10, o ‐phthalaldehyde (OPA) 11–14, 1‐fluoro‐2,4‐dinitrobenzene 15, 16, 11‐fluorenylmethyl chloroformate 17, or OPA‐β‐mercaptopropionic acid 18, 19, and postcolumn LC derivatization with OPA 20, 21 combined with fluorescence or UV detection have been described. However, these techniques are time consuming and give problems in quantification.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been described to determine netilmicin in pharmaceutical formulations and biological matrices. Precolumn derivatization LC with dansyl chloride [10], o-phthalaldehyde (OPA) [11][12][13][14], 1-fluoro-2,4-dinitrobenzene [15,16], 11-fluorenylmethyl chloroformate [17], or OPA-b-mercaptopropionic acid [18,19], and postcolumn LC derivatization with OPA [20,21] combined with fluorescence or UV detection have been described. However, these techniques are time consuming and give problems in quantification.…”
Section: Introductionmentioning
confidence: 99%
“…The traditional high-performance liquid chromatography (HPLC) methods measure Siso after derivatizing the free amino group with fluorescent reagents [2][3][4][5][6][7][8]. It is necessary to purify the samples after extraction in most detection methods.…”
Section: Introductionmentioning
confidence: 99%