1988
DOI: 10.1002/jhrc.1240110127
|View full text |Cite
|
Sign up to set email alerts
|

Determination of soil fumigants in air using tandem capillary gas chromatography after charcoal trapping

Abstract: is acknowledged for supplying the plasma samples tested. References[l] B. Hedback and L. S. Hermann, Acta Med. Scand. suppl. 681 (1984) 129-134. [2] M. Schomerus, B. Spiegelhalder, B. Stieren, and M. Eichelbaum, Cardiovasc. Res. 10 (1976) 605-61 2. G. Neugebauer, Cardiovasc. Res. 12 (1978) 247-254 G. M. Thomson and L. K. Pannell, J. Anal. Toxicol. 5 (1981) [3] [4] 105-1 09. [5] S. R. Harapat and R. . 70 (1981) V. K. Piotrovskii, D. 0. Ruminatsev, and V. 1. Metelitsa, J. Chromatogr. 275 (1983) 95-200. P. A. K… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1990
1990
2008
2008

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Berg and Jonsson's [34], Hagman and Jacobsson's [35,36] and Chrompack's MUSIC [37][38][39] vented Deans switches operated on the same principles as the design presented here, although they all used metal compression fittings in flow lines, and Hagman and Jacobsson used needle valves as restrictors on both the vent and the transfer line to the first dimension detector. The present design takes advantage of the development of press-tight connectors [40] to build inert, low volume, zero dead volume sample flow paths.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…Berg and Jonsson's [34], Hagman and Jacobsson's [35,36] and Chrompack's MUSIC [37][38][39] vented Deans switches operated on the same principles as the design presented here, although they all used metal compression fittings in flow lines, and Hagman and Jacobsson used needle valves as restrictors on both the vent and the transfer line to the first dimension detector. The present design takes advantage of the development of press-tight connectors [40] to build inert, low volume, zero dead volume sample flow paths.…”
Section: Discussionmentioning
confidence: 97%
“…Vented Deans switches were introduced in the mid-1980s [34][35][36], and a vented switch with a cold trap was at one time available from Chrompack as part of their , MUSIC' system [37][38][39], but an exhaustive search of the World Wide Web and the scientific literature yielded found no currently available equivalent.…”
Section: Introductionmentioning
confidence: 99%
“…A widely used method for trapping MITC from air is to perform cumulative sampling through charcoal tubes, followed by solvent elution and gas chromatographic determination using flame ionization or nitrogen−phosphorus detectors , . An alternative analytical method involves benzyl alcohol elution of charcoal in a sealed vial to release the MITC, followed by headspace gas chromatography .…”
Section: Methodsmentioning
confidence: 99%