2015
DOI: 10.1134/s0012500815030039
|View full text |Cite
|
Sign up to set email alerts
|

Determination of stability constants of inclusion complexes of betulin derivatives with β-cyclodextrin by capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
18
0
3

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(21 citation statements)
references
References 9 publications
0
18
0
3
Order By: Relevance
“…CE has advantages such as rapidity, high selectivity, small value of samples, and low operating costs. The most used approach is mobility shift ACE . In this method, binding constants are determined based on the change in electrophoretic mobilities of the studied compounds with varying the ligand content in BGE.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…CE has advantages such as rapidity, high selectivity, small value of samples, and low operating costs. The most used approach is mobility shift ACE . In this method, binding constants are determined based on the change in electrophoretic mobilities of the studied compounds with varying the ligand content in BGE.…”
Section: Introductionmentioning
confidence: 99%
“…Data on the thermodynamic parameters of the complexation of betulin derivatives with CDs in aqueous solutions are fragmentary. Recently, the interaction of betulin derivatives with β‐CD and with (2‐hydroxypropyl)‐β‐cyclodextrin and HP‐γ‐CD has been studied using ACE and PS‐CZE. The binding (stability) constants of the complexes were determined at 25°C.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ранее [12] нами был предложен способ исследования методом КЭ комплексов, образованных практически нерастворимыми соединениями, в частности комплексов включения бетулоновой кислоты с β-ЦД.…”
Section: Introductionunclassified
“…CE appeared in the 1980s and was rapidly developed due to transition to the silica capillaries with very small and regular diameters (tens of micrometers) and application of the straight detection in the fluid flow [22]. The CE and related electroseparation techniques are widely used for the estimation of stability constants because of rapidity, low cost of reagents, and high performance [23][24][25][26][27][28][29][30][31]. To study the interactions between a metal and ligand, several electropherograms are recorded with varying ligand content in background electrolytes (BGE) and metal solution injected as a sample.…”
Section: Introductionmentioning
confidence: 99%