2018
DOI: 10.3103/s1068371218090092
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the Parameters of a Compensating Unit in a Traction Power Supply System with a Booster Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…However, in almost half of the cases, the peaks were short-term. It is a common fact that atmospheric flows are changeable 18 , and plumes from elevated anthropogenic sources can meander either flowing into the station or passing by. In order to simplify the further analysis, the bursts lasting less than 2 hours were excluded from the research.…”
Section: Temporal Variability Of Sulfur Dioxide and Carbon Oxidementioning
confidence: 99%
“…However, in almost half of the cases, the peaks were short-term. It is a common fact that atmospheric flows are changeable 18 , and plumes from elevated anthropogenic sources can meander either flowing into the station or passing by. In order to simplify the further analysis, the bursts lasting less than 2 hours were excluded from the research.…”
Section: Temporal Variability Of Sulfur Dioxide and Carbon Oxidementioning
confidence: 99%
“…As can be seen from the bar chart, these differences usually differ by an average of 20-30%, so equalization of the voltage on-load tap-changer will be ineffective [1,6]. An automatic balancing current reduction device is proposed [1], which consists of a block of voltage addition and contains an input transformer, an rectifier [7,8], a voltage inverter, a rectifier filter, an output filter [9] and a voltage-boosting transformer [3]. The additional voltage is formed as follows.…”
Section: Application Of a Booster Transformermentioning
confidence: 99%
“…Thus, the energy indicators of the electrified railway are reduced, and Russian Railways Company incurs economic damage from imperfections in the interfacing of external and traction power supply systems. Some disadvantages in the joint operation of the external power supply system with the traction network are caused by the simultaneous electrification of the railway and settlements, industrial and agricultural loads in the regions [1][2][3].…”
Section: Introductionmentioning
confidence: 99%