2013
DOI: 10.2478/mms-2013-0018
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the Temperature Field Using Liquid Crystal Thermography and Analysis of Two-Phase Flow Structures in Research on Boiling Heat Transfer in a Minichannel

Abstract: The paper presents the application of liquid crystal thermography for temperature determination and visualisation of two phase flow images on the studied surface. Properties and applications of thermochromic liquid crystals are discussed. Liquid crystals were applied for two-dimensional detection of the temperature of the heating foil forming one of the surfaces of the minichannel along which the cooling liquid flowed. The heat flux supplied to the heating surface was altered in the investigation and it was ac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
28
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 24 publications
(28 citation statements)
references
References 19 publications
(23 reference statements)
0
28
0
Order By: Relevance
“…Application of the liquid crystal thermography for the detection of two-dimensional heating surface temperature distribution must be preceded using colour (hue); and temperature calibration is required. Detailed information about the accuracy of the heating foil temperature measurements with liquid crystal thermography and other experimental data errors are described in [7].…”
Section: Experimental Stand and Measurement Modulementioning
confidence: 99%
“…Application of the liquid crystal thermography for the detection of two-dimensional heating surface temperature distribution must be preceded using colour (hue); and temperature calibration is required. Detailed information about the accuracy of the heating foil temperature measurements with liquid crystal thermography and other experimental data errors are described in [7].…”
Section: Experimental Stand and Measurement Modulementioning
confidence: 99%
“…In evaluation, the absolute error of the void fraction was assumed to be equal to the area (point) comprising 0.0064 mm 2 ; this value was estimated on the basis of the resolution of the picture taken by a digital camera [6,8].…”
Section: " #mentioning
confidence: 99%
“…The accuracy of heating foil temperature measurements by using liquid crystal thermography and heat source efficiency measurement error in the same research set up were evaluated in [3,8]. The mean temperature measurement error of heating foil by liquid crystal thermography was 0.86 K. The relative volumetric heat flux measurement error amounted to 3.53%.…”
mentioning
confidence: 99%
See 2 more Smart Citations