2002
DOI: 10.1016/s0260-8774(01)00083-8
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the thermal diffusivity of ground beef patties under infrared radiation oven-shelf cooking

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
1

Year Published

2003
2003
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 9 publications
2
3
1
Order By: Relevance
“…However, the determined values of the thermal diffusivity changes, ranging from 1.35 · 10 À7 to 1.75 · 10 À7 m 2 s À1 , are consistent with those observed by Mitra et al (1995), i.e. 1.28 · 10 À7 and 1.52 · 10 À7 m 2 s À1 , as well as with those cited by Sheridan and Shilton (2002), i.e. 1.03 · 10 À7 and 2.10 · 10 À7 m 2 s À1 .…”
Section: Resultssupporting
confidence: 90%
See 1 more Smart Citation
“…However, the determined values of the thermal diffusivity changes, ranging from 1.35 · 10 À7 to 1.75 · 10 À7 m 2 s À1 , are consistent with those observed by Mitra et al (1995), i.e. 1.28 · 10 À7 and 1.52 · 10 À7 m 2 s À1 , as well as with those cited by Sheridan and Shilton (2002), i.e. 1.03 · 10 À7 and 2.10 · 10 À7 m 2 s À1 .…”
Section: Resultssupporting
confidence: 90%
“…The values calculated by this method ranged between about 3.5 · 10 À7 and about 4.5 · 10 À7 m 2 s À1 . The thermal diffusivities determined by method (A) differ significantly from the values cited by other authors and are approximately from two to three times higher then those reported by Roetzel et al (2003) and Sheridan and Shilton (2002) as well as Mitra, Kumar, Vedavarz, and Moallemi (1995).…”
Section: Resultscontrasting
confidence: 85%
“…Specifically, a was set at the numerical value that minimizes the mean square error between numerical solution and experimental results (Huang and Mittal, 1995). Results indicate that a can range from 1.72 Â 10 À7 to 1.80 Â 10 À7 m 2 /s for the samples examined; this is in line with previous studies by Sheridan and Shilton (2002), who report a = 1.84 Â 10 À7 m 2 /s for lean meat, and Huang and Mittal (1995), who suggest a = 1.80 Â 10 À7 m 2 /s, providing validation of the estimated values. Once a was determined, k was derived on the basis of typical q and c p values of meat available in literature.…”
Section: Theoretical Model For Cooking Meat and Validationsupporting
confidence: 80%
“…Using published values of the thermal diffusivity of lean beef, the time required to heat the middle spheres of beef to 71.1 • C (160 • F) can be calculated (Sheridan & Shilton, 2002). The desired middle temperature corresponds to the recommended USDA cooking temperature to ensure destruction of pathogens (Bernard, 2011).…”
Section: Recommendationsmentioning
confidence: 99%