2013
DOI: 10.1016/j.chroma.2013.03.035
|View full text |Cite
|
Sign up to set email alerts
|

Determination of tobacco-specific nitrosamines in replacement liquids of electronic cigarettes by liquid chromatography–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
153
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 204 publications
(163 citation statements)
references
References 22 publications
8
153
0
2
Order By: Relevance
“…As shown in the table, some substances not contained in a cigarette are contained in an e-cigarette. Kim and Shin (20) found that of carcinogenic nitrosamines specific to tobacco, nitrosonornicotine, 4-(nitrosomethylamino)-1-(3-pyridyl)-butanone, and nitrosoanatabine are also contained in an e-cigarette.…”
Section: Toxic Chemical Substances It Containsmentioning
confidence: 99%
“…As shown in the table, some substances not contained in a cigarette are contained in an e-cigarette. Kim and Shin (20) found that of carcinogenic nitrosamines specific to tobacco, nitrosonornicotine, 4-(nitrosomethylamino)-1-(3-pyridyl)-butanone, and nitrosoanatabine are also contained in an e-cigarette.…”
Section: Toxic Chemical Substances It Containsmentioning
confidence: 99%
“…32 Tobacco-specific nitrosamines are highly carcinogenic, but the low levels found in most ENDS products are unlikely to pose a substantial risk. 33 Certain ENDS emissions can impact the viability of established cultured cell lines, however, to a lesser degree than cigarette smoke. 34,35 The emission usually contains some carcinogens and other toxins found in tobacco smoke at average levels of 1-2 times lower than in tobacco smoke, but higher than in a nicotine inhaler.…”
Section: Aldehydesmentioning
confidence: 99%
“…A variety of mobile phases were tested for LC-MS/MS analysis of the NNN and NNK (data not shown) following the different combinations reported in the literature (Kim and Shin, 2013). The conditions selected for use, due to excellent sensitivity achieved, were 10 mM ammonium formate in methanol and 10 mM ammonium formate in water with a ratio of 70% to 30%.…”
Section: Lc-ms/msmentioning
confidence: 99%
“…Until recently the majority of these reports used GC coupled with thermal energy analyser (TEA) (Carmella et al, 2000, Stepanov et al, 2002 or mass spectrometry (MS) (Song and Ashley, 1999, Zhou et al, 2007, Sleiman et al, 2009), or HPLC with various detectors such as UV (Hecht et al, 1975), or TEA (Hoffmann et al, 1979). It is now more common to see LC-MS/MS being used extensively for quantitative analysis of TSNAs (Kim and Shin, 2013, Wagner et al, 2005, Wu et al, 2008, Ding et al, 2008, Xiong et al, 2010, Jansson et al, 2003 due to its high sensitivity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation