2015
DOI: 10.1007/s12161-015-0264-x
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Trace Amounts of Cd(II), Cu(II), and Ni(II) in Food Samples Using a Novel Functionalized Magnetic Nanosorbent

Abstract: This work describes a novel sorbent based on functionalization of magnetic nanoparticles by 2-aminobenzothiazole and its application in the extraction and preconcentration of trace amount of Cd(II), Cu(II), and Ni(II) ions. This nanosorbent was characterized by Fourier transfer infrared spectroscopy, thermal analysis, X-ray powder diffraction, elemental analysis, and scanning electron microscopy. The effects of various factors such as pH value, sorption time, sorbent dosage, type, volume, and concentration of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(11 citation statements)
references
References 51 publications
0
11
0
Order By: Relevance
“…Magnetic complexes with CNTs were reported for preconcentration/separation of U(IV), Cd(II), As(III), As(V), Ni(II), Pb(II), Zn(II) etc. [ 145 , 146 , 147 , 148 , 149 ]. However, sorption capacity and affinity of the analyte to CNTs can be improved by the attachment of additional ligands [ 148 , 150 ].…”
Section: Magnetic Nanoparticles In the Real Worldmentioning
confidence: 99%
“…Magnetic complexes with CNTs were reported for preconcentration/separation of U(IV), Cd(II), As(III), As(V), Ni(II), Pb(II), Zn(II) etc. [ 145 , 146 , 147 , 148 , 149 ]. However, sorption capacity and affinity of the analyte to CNTs can be improved by the attachment of additional ligands [ 148 , 150 ].…”
Section: Magnetic Nanoparticles In the Real Worldmentioning
confidence: 99%
“…In order to confirm the solid structure of the hybrid, the powder X-ray diffraction (XRD) patterns of HMT-STA and MAC-HMT-STA-MB are collected in Figure 3 re from MAC [8,28,36,37]. Therefore, the primary structure of POM has remained intact in the solid structure of composite.…”
Section: Resultsmentioning
confidence: 99%
“…The sample volume is a critical factor for the development of an extraction technique because the preconcentration factor is directly proportional to it. [38][39][40][41][42][43] Herein, the effect of the sample volume on the recovery% was tested in the range of 10 mL to 45 mL. The results in Fig.…”
Section: Effect Of the Sample Volumementioning
confidence: 99%