Determination of ultra-low 236U/238U isotope ratios by tandem quadrupole ICP-MS/MS

Abstract: Isotope ratios of 236 U/ 238 U were measured at levels below 10 À7 by single collector ICPMS with a tandem quadrupole mass separation mechanism. Peak tailing of the prominent 238 U + ion beam on the 236 U + peak was reduced to the level of $10 À10 by use of two quadrupole mass filters. The 235 UH + interference on 236 U + was efficiently reduced to a UH + /U + ratio of 1 Â 10 À8 by an ion-molecule reaction between UH + and O 2 in a collision/reaction cell placed between the two quadrupoles. The resultant detec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
0
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(58 citation statements)
references
References 17 publications
0
56
0
2
Order By: Relevance
“…Precise 236U measurements were performed twice in two different laboratories: at CEA/LANIE ("Commissariat à l'Energie Atomique et aux Energies Alternatives/ Laboratoire de développement Analytique Nucléaire, Isotopique, Elémentaire") and at IRSN/LELI ("Institut de Radioprotection et de Sureté du Nucléaire / Laboratoire sur le devenir des pollutions des sites radioactifs") using two ICP-MS/MS (Agilent 8800, Agilent Technologies, Tokyo, Japan) instruments well-suited for the measurement of extremely low 236U/238U isotope ratios (Tanimizu et al, 2013;Yang et al, 2016). Two analyses on each sample were conducted to provide more confidence in the results.…”
Section: Uranium Measurements By Mass Spectrometrymentioning
confidence: 99%
“…Precise 236U measurements were performed twice in two different laboratories: at CEA/LANIE ("Commissariat à l'Energie Atomique et aux Energies Alternatives/ Laboratoire de développement Analytique Nucléaire, Isotopique, Elémentaire") and at IRSN/LELI ("Institut de Radioprotection et de Sureté du Nucléaire / Laboratoire sur le devenir des pollutions des sites radioactifs") using two ICP-MS/MS (Agilent 8800, Agilent Technologies, Tokyo, Japan) instruments well-suited for the measurement of extremely low 236U/238U isotope ratios (Tanimizu et al, 2013;Yang et al, 2016). Two analyses on each sample were conducted to provide more confidence in the results.…”
Section: Uranium Measurements By Mass Spectrometrymentioning
confidence: 99%
“…Probably it is due to the formation of the 35 Cl 16 3 , both dioxide ions were selected in Q2 causing the positive interference. Probably it is due to the formation of the 35 Cl 16 3 , both dioxide ions were selected in Q2 causing the positive interference.…”
Section: View Article Onlinementioning
confidence: 99%
“…The authors emphasized the need for CRI, once matrix matching calibration and ICP-MS operation in standard mode did not suffice to improve the accuracy, especially in ammonium acetate medium. 16,17 Arsenic and selenium at ultratrace levels were determined as AsCH 2 + and SeCH 2 + employing CH 3 F/He as a reaction gas in ICP-MS/MS. These pressurized cells are located before the quadrupole analyzer and gases such as O 2 , NH 3 and H 2 are introduced into the cell promoting collision or reaction processes.…”
Section: Introductionmentioning
confidence: 99%
“…При этом количество и имя направляемых в ORS и далее в главный масс-анализатор разновидностей ионов задают указа-нием индивидуальных величин или диапазона их масс в Q1 и Q2: от одной до множества. Накоплен-ный к настоящему времени двухлетний опыт разно-образного применения Agilent 8800 ICP-QQQ опу-бликован в [129][130][131][132][133][134][135][136][137][138][139][140][141][142][143][144][145][146][147].…”
Section: оптика масс-спектрометра Agilent 8800 Icp-qqqunclassified