1985
DOI: 10.1016/0009-8981(85)90335-3
|View full text |Cite
|
Sign up to set email alerts
|

Determination of urinary cortisol and 6β-hydroxycortisol by high performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
7
1

Year Published

1985
1985
2012
2012

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 21 publications
1
7
1
Order By: Relevance
“…The h.p.l.c. method we used was validated on the basis of the following points: (1) Our data for healthy adults were in good agreement with previously published values (Dumont et al, 1984;Nakamura & Yakata, 1985;Hosoda et al, 1981;Kishida & Fukushima, 1983;Nahoul et al, 1982;Park, 1978;Zhiri et al, 1986;Desage et al, 1987). (2) In addition we had the opportunity, in a separate study, to perform both our h.p.l.c.…”
Section: Other Monooxygenase Assayssupporting
confidence: 79%
See 1 more Smart Citation
“…The h.p.l.c. method we used was validated on the basis of the following points: (1) Our data for healthy adults were in good agreement with previously published values (Dumont et al, 1984;Nakamura & Yakata, 1985;Hosoda et al, 1981;Kishida & Fukushima, 1983;Nahoul et al, 1982;Park, 1978;Zhiri et al, 1986;Desage et al, 1987). (2) In addition we had the opportunity, in a separate study, to perform both our h.p.l.c.…”
Section: Other Monooxygenase Assayssupporting
confidence: 79%
“…Various h.p.l.c. systems, as well as immunoassays, have been described for this measurement (Dumont et al, 1984;Nakamura & Yakata, 1985;Hosoda et al, 1981;Kishida & Fukushima, 1983;Nahoul et al, 1982;Park, 1978;Zhiri et al, 1986;Desage et al, 1987). The h.p.l.c.…”
Section: Other Monooxygenase Assaysmentioning
confidence: 99%
“…We tested several compounds for use as internal standards such as 6␤-hydroxytestosterone, dexamethasone [26,27], methylprednisolone [33], and beclomethsone for the HPLC analysis of 6␤-OHF and cortisol. Dexamethasone has been widely used as the internal standard [26,27], but an interfering peak was observed at t R 28.80 min derived from urine (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…The HPLC method generally offers higher selectivity in measuring urinary 6␤-OHF [23][24][25][26][27][28][29][30], but the results are not often reproducible in quantitation of 6␤-OHF in urine, because of polar interferences and low recoveries of 6␤-OHF.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation