Determination of vinpocetine and its primary metabolite, apovincaminic acid, in rat plasma by liquid chromatography–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 21 publications
(22 citation statements)
references
References 24 publications
1
21
0
Order By: Relevance
“…Similarly, ions at m/z 236.1439 and 222.1277 were formed by loss of CO 2 from m/z 280.1347 and 266.1189, respectively. The ions at m/z 208.1128 and 193.0941 were produced by consecutive losses of C 2 H 4 and CH 3 from m/z 236.1439 …”
Section: Resultsmentioning
confidence: 99%
“…Similarly, ions at m/z 236.1439 and 222.1277 were formed by loss of CO 2 from m/z 280.1347 and 266.1189, respectively. The ions at m/z 208.1128 and 193.0941 were produced by consecutive losses of C 2 H 4 and CH 3 from m/z 236.1439 …”
Section: Resultsmentioning
confidence: 99%
“…Stock solution stability was performed at room temperature and at 4°C by comparing the area response of a stability sample of analytes and internal standard with the area response of sample prepared from fresh stock solutions. The results should be within the acceptable limit of ±10% change for the stock solution stability experiment (Xia et al ., ). Bench‐top stability of extracted samples, room temperature stability, refrigerated stability of extracted sample at 4°C, freeze–thaw stability and long term stability at −20°C were performed at 5.00, 100 and 750 ng/mL using five replicates at each concentration.…”
Section: Methodsmentioning
confidence: 97%
“…The characteristics of the proposed method have been compared to earlier reported methods. Jiang et al [14] reported a LC-MS-MS method using MRM by positive ionization mode to determine VP and AVA in rat plasma. In their paper, the procedure of sample preparation was multistep and costly by SPE, and conditions of LC separation and MS quantification were very different from n is the number of the sample in a batch, N is the batch number those in our work.…”
Section: Comparisons With Other Methodsmentioning
confidence: 99%
“…AVA was detectable by MS not only in negative mode, but also in positive mode [13,14]. In this proposal, the response in positive mode was more acute than that in negative mode using mobile containing acetonitrile water with formic acid.…”
Section: Ms-ms Conditionsmentioning
confidence: 99%
See 1 more Smart Citation