“…In conditions shown as shaded portion, on the other hand, tungsten oxide is reduced with hydrogen. It has been found that 24 at% of oxygen was detected in the W layer formed at a temperature of 70 • C but no oxygen was detected in that formed at a temperature of 140 • C [5]. In our recent study, it seemed that when the substrate temperature was higher than about 100 • C, a large amount of oxygen was not retained in a W layer.…”