2012
DOI: 10.2172/1043778
|View full text |Cite
|
Sign up to set email alerts
|

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

Abstract: NOTICEThis report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial produc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 5 publications
0
15
0
Order By: Relevance
“…n is the number of effective parameters that is determined according to previous researches. This value is 5 for CoFRMC type IEC [31][32][33][34][35], 6 for PCoFMC type IEC [36,37], and 10 for the DEH subsystem [2,8,15,16].…”
Section: Stepwise Regression Method Srmmentioning
confidence: 99%
See 1 more Smart Citation
“…n is the number of effective parameters that is determined according to previous researches. This value is 5 for CoFRMC type IEC [31][32][33][34][35], 6 for PCoFMC type IEC [36,37], and 10 for the DEH subsystem [2,8,15,16].…”
Section: Stepwise Regression Method Srmmentioning
confidence: 99%
“…These types of IECs improve the performance of the cooling system by redirecting a portion of the cooled air (product air) to the working air channels. Like all previous published literatures regarding DEVAP system [2,7,8,13,15,16], in this survey the counter types of Mcycles (CoFRMC and PCoFMC) were considered and modeled as the second part of the DEVAP system. …”
Section: Desiccant-enhanced Evaporative Devap Cooling Systemmentioning
confidence: 99%
“…Another common technological pairing is with evaporative based cooling technology, to create 'stand-alone' systems. Evaporative based cooling compliments liquid desiccant due to its improved performance when operated with dry air and its low electrical requirement (Daou, Wang et al, 2006;Ouazia, Barhoun et al, 2009;Kozubal, Woods et al, 2011;Kozubal, Woods et al, 2012). Currently, it is reported that hybrid systems are most widely used.…”
Section: Liquid Desiccant Air Conditioning Systems and Performancementioning
confidence: 99%
“…In addition to the LD-IDECOAS proposed by Kim et al [1,2], Kozubal et al [8] proposed a desiccant-enhanced evaporative air conditioner (DEVap) for air conditioning common buildings. Buker et al [9] proposed and empirically analyzed a similar air-handling system [1,2,8], which was integrated with a photovoltaic and a thermal roof collector as regeneration heat sources.…”
Section: Introductionmentioning
confidence: 99%
“…Buker et al [9] proposed and empirically analyzed a similar air-handling system [1,2,8], which was integrated with a photovoltaic and a thermal roof collector as regeneration heat sources. Gao et al [10] proposed and evaluated the system performance of a solid-desiccant-enhanced, counter-flow indirect evaporative cooling system.…”
Section: Introductionmentioning
confidence: 99%