1997
DOI: 10.1016/s1056-8719(97)00095-6
|View full text |Cite
|
Sign up to set email alerts
|

Development and pharmacological characterization of a modified procedure for the measurement of carbonic anhydrase activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
17
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 5 publications
0
17
0
Order By: Relevance
“…The IC 50 values of inhibitors (4)(5)(6)(7)(8)(9)(10)(11)(12) were assayed by the hydrolysis of p-nitrophenyl acetate on the esterase activities of CA isoenzymes in the presence of various inhibitor concentrations. The absorbance was determined at 348 nm after 3 min 27 . Regression analysis graphs were drawn by plotting inhibitor concentrations versus enzyme activity.…”
Section: Determination Of Ic 50 and K I Values Of Compoundsmentioning
confidence: 99%
“…The IC 50 values of inhibitors (4)(5)(6)(7)(8)(9)(10)(11)(12) were assayed by the hydrolysis of p-nitrophenyl acetate on the esterase activities of CA isoenzymes in the presence of various inhibitor concentrations. The absorbance was determined at 348 nm after 3 min 27 . Regression analysis graphs were drawn by plotting inhibitor concentrations versus enzyme activity.…”
Section: Determination Of Ic 50 and K I Values Of Compoundsmentioning
confidence: 99%
“…The K i values were determined as described in the literature [34][35][36][37][38]. According to this study, in its first part, the IC 50 values were obtained as in vitro.…”
Section: Determination Of K I Valuesmentioning
confidence: 99%
“…IC 50 values of the inhibitors (for the synthesised compounds 8-18, with 1 and 2 as the control compounds) were assayed by the hydrolysis of 4-nitrophenylacetate on the esterase activities of the CA isoenzymes in the presence of various inhibitor concentrations. The absorbance was determined at 348 nm after 3 min [34]. Regression analysis graphs were drawn by the plotting inhibitor concentrations versus the enzyme activity by using the Microsoft Excel Program.…”
Section: Determination Of K I Valuesmentioning
confidence: 99%
“…The method for determination of Ki values is described elsewhere [47][48][49][50][51] . In the first part of this study, IC 50 values have been obtained as in vitro.…”
Section: Determination Of K I Valuesmentioning
confidence: 99%
“…IC 50 of the inhibitors (the synthesized compounds 2a-f, 1 and AAZ as the control compound) were assayed by the hydrolysis of p-nitrophenylacetate on esterase activities of CA isoenzymes in the presence of various inhibitor concentrations. The absorbance was determined at 348 nm after 3 min 47 . Regression analysis graphs were drawn by plotting inhibitor concentrations versus enzyme activity by using Microsoft Excel Program.…”
Section: Determination Of K I Valuesmentioning
confidence: 99%