Development and research on integrated protection system based on redundant information analysis

Abstract: Facing the growth of energy demand and the worldwide interests in renewable energy sources, smart grid has been proposed in order to accommodate the needs of power grid development. In China, digital substations have been widely applied. Moreover, as the worldwide interest and development in smart grid have increased significantly, the digital information availability and communication capability of modern substation have been improved. Different with traditional substation protection configuration based on lo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…For a profound insight into wide power-outages originating from various unsettling events, it is useful to hypothetically divide power system operation into five situations as depicted in Fig. 14(a) [42].…”
Section: Predictive Wide-area Monitoring Protection and Controlmentioning
confidence: 99%
“…For a profound insight into wide power-outages originating from various unsettling events, it is useful to hypothetically divide power system operation into five situations as depicted in Fig. 14(a) [42].…”
Section: Predictive Wide-area Monitoring Protection and Controlmentioning
confidence: 99%
“…Most distributed protection and distributed optimization are inseparable from information sharing. In [27], the integrated protection is proposed to realize more reliable and sensitive fault detection by sharing information and cooperation among different protection functions.…”
Section: Information Security Requirements Of the System Operation Layermentioning
confidence: 99%
“…Fault line identification by comparing the current amplitude difference, which is suitable for system with small-capacity DG integration, but not applicable to system with large-capacity DG integration, is described in [35]. The authors in [36][37][38] made a combination of the startup information of protection relays in neighbouring regions to determine the fault region, with small data scale and high computation speed. However, the multi-branch structure of distribution network was not considered, thus the protection operation criterion was not universally applicable.…”
Section: Introductionmentioning
confidence: 99%