2004 IEEE International Reliability Physics Symposium. Proceedings
DOI: 10.1109/relphy.2004.1315431
|View full text |Cite
|
Sign up to set email alerts
|

Development and use of a miniaturized health monitoring device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 1 publication
0
10
0
Order By: Relevance
“…The implementation of the methodology, which has been validated [7], is the following: -First, the environment surrounding the electronic assembly to be monitored should be known (a TSMD can be used). -Second, field returns or simulation results of the electronic assembly to be monitored have to be collected according to the environment, in order to construct a matrix of cycles to failure (CTF) depending on the two most damageable parameters of thermal stresses: the temperature amplitude and the mean temperature.…”
Section: Methodology For On-board Prognosticsmentioning
confidence: 99%
See 1 more Smart Citation
“…The implementation of the methodology, which has been validated [7], is the following: -First, the environment surrounding the electronic assembly to be monitored should be known (a TSMD can be used). -Second, field returns or simulation results of the electronic assembly to be monitored have to be collected according to the environment, in order to construct a matrix of cycles to failure (CTF) depending on the two most damageable parameters of thermal stresses: the temperature amplitude and the mean temperature.…”
Section: Methodology For On-board Prognosticsmentioning
confidence: 99%
“…The second tool is the HUMS (health and usage monitoring system) [2] which, once the operating environment is known, embeds some additional processing but still needs to store some data for off-board complementary analysis. The last family is represented by diagnostics and prognostics systems, which process the data in real time and provide relevant information without any ground-based support and storage needs.…”
Section: Introductionmentioning
confidence: 99%
“…9 Considering equipment character, environmental profile, associated complexity, and so on, it is unnecessary to measure and record all ESs. 1,8,10 Only MESs should be selected. Let R MESs denote the set of MESs.…”
Section: Main Environmental Stresses and Key Characteristic Parametermentioning
confidence: 99%
“…1,8,10 Time stress measurement module (TSMM) in aircraft systems developed by Unisys Corporation was only designed to measure temperature, vibration, and shock data. 8 Grumman Aerospace and Electronics Group selected vibration and temperature for environmental testing.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation