Development and validation of a quantitative assay based on tandem mass spectrometry

Abstract: Many routine hospital and clinical research assays have relied upon immunoassay procedures to achieve sensitive measurements of a range of important analytes. Some of the methods have been developed in-house but increasingly commercial kits and automated analysers have become commonplace. The accuracies of these methods are under question in health care. Mass spectrometry (MS) is potentially a more accurate technique with the ability to demonstrate specificity. An introduction of the basic analytical aspects o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
81
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 115 publications
(81 citation statements)
references
References 66 publications
0
81
0
Order By: Relevance
“…Assay is fully validated 190,191 196 In salvage therapy for invasive aspergillosis, response rate increased with increasing serum levels and in patients with average levels above 1.25 mg/L response rate was 75% 197 Table 6 summarises therapeutic ranges for itraconazole, voriconazole and posaconazole, and Table 7 lists the suggested indications for TDM. Use of TDM is becoming more widespread and data from reference laboratories indicate that therapeutic levels are not achieved in a significant proportion of routine samples.…”
Section: Therapeutic Drug Monitoring (Tdm)mentioning
confidence: 99%
“…Assay is fully validated 190,191 196 In salvage therapy for invasive aspergillosis, response rate increased with increasing serum levels and in patients with average levels above 1.25 mg/L response rate was 75% 197 Table 6 summarises therapeutic ranges for itraconazole, voriconazole and posaconazole, and Table 7 lists the suggested indications for TDM. Use of TDM is becoming more widespread and data from reference laboratories indicate that therapeutic levels are not achieved in a significant proportion of routine samples.…”
Section: Therapeutic Drug Monitoring (Tdm)mentioning
confidence: 99%
“…Liquid chromatography coupled to tandem quadrupole mass spectrometry (LC-MS/MS) is widely used as a powerful tool for quantifying target analytes in clinical chemistry laboratories, owing to the selectivity provided by multiple reaction monitoring (MRM) (1)(2)(3). 3 However, for a number of assays, interferences exist that can cause falsely increased values when using MRM detection (4 -7 ).…”
mentioning
confidence: 99%
“…3 However, for a number of assays, interferences exist that can cause falsely increased values when using MRM detection (4 -7 ).…”
mentioning
confidence: 99%
See 2 more Smart Citations