2019
DOI: 10.1016/j.jchromb.2019.121723
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of an LC-MS/MS method with a broad linear dynamic range for the quantification of tivozanib in human and mouse plasma, mouse tissue homogenates, and culture medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…The idea of expanding the linear dynamic range of LC-MS/MS assays using isotopologue transitions were later adopted by several other researchers, for example in the quantification of methamphetamine in urine, 6 in the assessment of 80 forensically relevant compounds in 11 different postmortem sample matrices, 7 and in the quantification of tivozanib in human and mouse plasma and mouse tissue homogenates. 8 A summary of literature reported applications of multiple isotopologue transitions in expanding LC-MS/MS assay linear dynamic range is provided in Table 1.…”
Section: Key Literature Reports Of the Utilization Of Isotopologues T...mentioning
confidence: 99%
“…The idea of expanding the linear dynamic range of LC-MS/MS assays using isotopologue transitions were later adopted by several other researchers, for example in the quantification of methamphetamine in urine, 6 in the assessment of 80 forensically relevant compounds in 11 different postmortem sample matrices, 7 and in the quantification of tivozanib in human and mouse plasma and mouse tissue homogenates. 8 A summary of literature reported applications of multiple isotopologue transitions in expanding LC-MS/MS assay linear dynamic range is provided in Table 1.…”
Section: Key Literature Reports Of the Utilization Of Isotopologues T...mentioning
confidence: 99%
“…All other chemicals and reagents were obtained from Sigma-Aldrich (Steinheim, Germany). All chemicals used in the tivozanib assay were described before (Bruin et al 2019).…”
Section: Chemicalsmentioning
confidence: 99%
“…Tivozanib concentrations in cell culture medium, plasma and tissue homogenates were analyzed with a previously reported liquid-chromatography tandem mass spectrometric (LC-MS/MS) assay, using a deuterated internal standard (Bruin et al 2019).…”
Section: Lc-ms/ms Analysismentioning
confidence: 99%