2018
DOI: 10.1016/j.foodchem.2017.07.070
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of HPLC method for the determination of ferrocyanide ion in food grade salts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…A method developed for an HPLC procedure must accurate, sensitive, and able to identify an analyte with high selectivity. For this purpose, validation of analytical methods should include assessments of linearity, selectivity, accuracy (recovery), precision, LOD, LOQ, and measurement uncertainty [15]. In our study, the UV spectrum of the HA in the mobile phase was scanned in the region between 190 and 800 nm.…”
Section: Resultsmentioning
confidence: 99%
“…A method developed for an HPLC procedure must accurate, sensitive, and able to identify an analyte with high selectivity. For this purpose, validation of analytical methods should include assessments of linearity, selectivity, accuracy (recovery), precision, LOD, LOQ, and measurement uncertainty [15]. In our study, the UV spectrum of the HA in the mobile phase was scanned in the region between 190 and 800 nm.…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, there are also studies that use the same solvent for both standard and sample preparation. For instance, Lim et al [25] analyzed ferrocyanide ions using HPLC-UV by employing the same solvent (0.02 M NaOH solution) for the preparation of the standard solution and pretreatment of the sample. In addition, Klimczak and Gliszczyńska-Świgło [27] quantified vitamin C (ascorbic acid and dehydroascorbic acid) using HPLC and ultraperformance liquid chromatography (UPLC) systems by using 10% meta-phosphoric acid solvent to both extract the samples and dilute the standard solutions.…”
Section: Resultsmentioning
confidence: 99%
“…The FI system was successfully applied to determine ferrocyanide at mg/kg level in real salt samples with a precision better than 3% and quantitative recovery. Lim et al (2018) developed and validated a rapid high-performance liquid chromatography (HPLC) method to determine the presence of ferrocyanide ions ([Fe(CN) 6 ] 4-) in food grade salts (sodium chloride). An analytical column coupled with a guard column and mobile phase comprised of sodium perchlorate and sodium hydroxide were employed with a photodiode array detector set at a wavelength of 221 nm.…”
Section: Methods Of Analysis In Foodmentioning
confidence: 99%