Development and Validation of Stability Indicating HPLC Method for Simultaneous Estimation of Amoxicillin and Clavulanic Acid in Injection

Abstract: A simple, fast, precise, accurate and rugged stability indicating high performance liquid chromatography (HPLC) method has been developed for simultaneous estimation of Amoxicillin and Clavulanic acid from injectable dosage form. The stability indicating capability of the method was proven by subjecting the drugs to stress conditions as per ICH recommended test conditions such as alkaline and acid hydrolysis, oxidation, photolysis, thermal degradation and resolution of the degradation products formed therein. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 10 publications
0
11
0
Order By: Relevance
“…Several analytical methods have been reported for the quantitative estimation of amoxicillin in bulk drug, pharmaceutical formulation and biomedical samples. These are high pressure liquid chromatography (HPLC), UV spectroscopy and spectrophotometric, electrochemical sensor, chemometric, imprinted sensor, fluorescence sensor, electrochemiluminescence and chemiluminescence methods These reported methods have the advantage of accuracy and precision but they also have some limitations such as being expensive, time consuming, requiring sophisticated instruments and some of these methods require large amount of high purity organic solvents. Therefore, there is a vital need to develop a rapid, simple, selective, sensitive and cost‐effective method for pharmaceutical and biomedical analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Several analytical methods have been reported for the quantitative estimation of amoxicillin in bulk drug, pharmaceutical formulation and biomedical samples. These are high pressure liquid chromatography (HPLC), UV spectroscopy and spectrophotometric, electrochemical sensor, chemometric, imprinted sensor, fluorescence sensor, electrochemiluminescence and chemiluminescence methods These reported methods have the advantage of accuracy and precision but they also have some limitations such as being expensive, time consuming, requiring sophisticated instruments and some of these methods require large amount of high purity organic solvents. Therefore, there is a vital need to develop a rapid, simple, selective, sensitive and cost‐effective method for pharmaceutical and biomedical analysis.…”
Section: Introductionmentioning
confidence: 99%
“…High Performance Liquid Chromatography (HPLC) analysis was performed, for each molecule under study, based on previous reported methods 24 , 25 . CLV and IMP were measured using a VWR Hitachi LaChromElite equipped with column oven, auto sampler, and UV-DAD detector.…”
Section: Methodsmentioning
confidence: 99%
“…The analysis was carried out on HPLC system using the column Inertsil C18 (5µm, 250×4.6mm); with UV detection of 249 nm, column temperature was maintained upto 37 0 C. The injection volume used was 20µl with a flow rate of 1.0ml/min. [6,7]…”
Section: Methods Development Chromatographic Conditionsmentioning
confidence: 99%