2019
DOI: 10.1016/j.foodchem.2019.02.011
|View full text |Cite
|
Sign up to set email alerts
|

Development of a broad-spectrum monoclonal antibody-based indirect competitive enzyme-linked immunosorbent assay for the multi-residue detection of avermectins in edible animal tissues and milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(24 citation statements)
references
References 35 publications
0
24
0
Order By: Relevance
“…A cross-reactivity (CR) study was performed to determine the specificity of this mAb. 23 DAS, T-2, HT-2, DON, and NIV were subjected to ic-ELISA. The CR values were calculated by the following formula: …”
Section: Methodsmentioning
confidence: 99%
“…A cross-reactivity (CR) study was performed to determine the specificity of this mAb. 23 DAS, T-2, HT-2, DON, and NIV were subjected to ic-ELISA. The CR values were calculated by the following formula: …”
Section: Methodsmentioning
confidence: 99%
“…Indirect competitive immunoassay, containing IC-ELISA and IC-TRFIA which were the most common method for the small molecule hazards (such as small molecule pesticides, biotoxins and antibiotics, etc.) determination (Kavanagh, Elliott, & Campbell, 2015;Ni et al, 2019;Watanabe, Miyake, & Yogo, 2013). Because of its superiority, the key evaluation index of antibody to antigen, containing IC 10 (LOD), IC 50 and IC 20 -IC 80 (linear working range), which could be calculated out directly.…”
Section: Ic-trfia Establishment Of Van and Its Analoguesmentioning
confidence: 99%
“…The approaches include high-performance liquid chromatography-ultraviolet detection (HPLC-UV) 4 , liquid chromatography-tandem mass spectrometry (LC-MS) 6 , high-performance liquid chromatographyuorescent detector (HPLC-FLD) 7 , enzyme-linked immunosorbent assay (ELISA) 8 and liquid chromatography-tandem mass spectrometry/mass spectrometry (HPLC-MS/MS) 9 . However, these approaches either needed a time-consuming process, high-cost accurate instrument, or high professional operators, which makes them di cult to apply in general laboratories 10 . Herein, considering the potential harm of abamectin B 1 for public health, a convenient and accurate analysis method for residual abamectin B 1 is necessary 10,11 .…”
Section: Introductionmentioning
confidence: 99%
“…However, these approaches either needed a time-consuming process, high-cost accurate instrument, or high professional operators, which makes them di cult to apply in general laboratories 10 . Herein, considering the potential harm of abamectin B 1 for public health, a convenient and accurate analysis method for residual abamectin B 1 is necessary 10,11 . Therefore, it is necessary to explore a convenient analysis method for detection of residual abamectin B 1 to reduce the potential harm to public health.…”
Section: Introductionmentioning
confidence: 99%