2021
DOI: 10.1016/j.jhazmat.2020.123781
|View full text |Cite
|
Sign up to set email alerts
|

Development of a fast and ultrasensitive black phosphorus-based colorimetric/photothermal dual-readout immunochromatography for determination of norfloxacin in tap water and river water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(15 citation statements)
references
References 12 publications
0
15
0
Order By: Relevance
“…It has already been outlined that LFIAs own all the features to satisfy the ASSURED criteria. Recently, these criteria have been revised by adding three criteria, namely, real-time connectivity, ease of specimen collection, and environmental friendliness to assemble the so-called REASSURED criteria [ 239 ]. Unsurprisingly LFIA can already meet almost all of these additional desiderata.…”
Section: Future Perspectivesmentioning
confidence: 99%
“…It has already been outlined that LFIAs own all the features to satisfy the ASSURED criteria. Recently, these criteria have been revised by adding three criteria, namely, real-time connectivity, ease of specimen collection, and environmental friendliness to assemble the so-called REASSURED criteria [ 239 ]. Unsurprisingly LFIA can already meet almost all of these additional desiderata.…”
Section: Future Perspectivesmentioning
confidence: 99%
“…Therefore, 10 min was adopted for the subsequent experiments. Lastly, the volume of probes also played an essential role since the visualization of test zone were ascribed to the accumulation of probes on T-lines . As shown in Figure e, 80 μL 50 μg/mL Au–PMBA probes were separately selected as the suitable volume for this system.…”
Section: Resultsmentioning
confidence: 99%
“…To date, some ICA methods have been reported as summarized in Table S1, † which showed differences in sensitivity and specificity to FQ compounds. For example, Ren et al developed an ultrasensitive black phosphorus-based ICA for quantitative determination of NOR in water with a limit of detection (LOD) of 0.045 µg L −1 , 6 Xiao et al developed a colloidal gold-based ICA for the qualitative detection of 11 FQs in fish with LOD of 4 μg kg −1 , 29 and Peng et al constructed a colloidal gold-based ICA for the analysis of 32 FQs in milk with LOD values of 0.1-10 µg L −1 . 30 Although these methods have good performance for one or some FQs, a more sensitive method is still needed for the simultaneous determination of the banned LOM, PEF, OFL and NOR.…”
Section: Introductionmentioning
confidence: 99%
“…1 As with other antibiotics, the development of antimicrobial resistance caused by long-term exposure to FQ resides in food constitutes a major threat to human health. 6,7 In addition, some other adverse effects have also been reported, such as tendon toxicity, cardiotoxicity, central nervous system toxicity, and arthropathy. 8,9 In order to reduce the risk of drug residues, maximum residue limits (MRLs) for some FQs in foodstuffs have been set by the European Union (EU), China, Japan and other countries.…”
Section: Introductionmentioning
confidence: 99%