2020
DOI: 10.2514/1.t5688
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Fast-Response Diamond Calorimeter Heat Transfer Gauge

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…However, the surface junction thermocouples used in the present work are a relatively new matching-taper design relying on an oxide insulating layer and are suitable for operation at high temperatures. Previous experiments [18,16] have demonstrated the utility of these rugged devices in expansion tunnel flows with durations of up to 200 µs with peak heat transfer rates in excess of 100 MW m −2 . The present work investigates the application of these thermocouples in the low enthalpy, but long duration flows of TUSQ for the measurement of the time-averaged and fluctuating components of heat flux and flow stagnation temperature.…”
Section: Atomic Layer Thermopile (Altp) Sensors Have Amentioning
confidence: 99%
“…However, the surface junction thermocouples used in the present work are a relatively new matching-taper design relying on an oxide insulating layer and are suitable for operation at high temperatures. Previous experiments [18,16] have demonstrated the utility of these rugged devices in expansion tunnel flows with durations of up to 200 µs with peak heat transfer rates in excess of 100 MW m −2 . The present work investigates the application of these thermocouples in the low enthalpy, but long duration flows of TUSQ for the measurement of the time-averaged and fluctuating components of heat flux and flow stagnation temperature.…”
Section: Atomic Layer Thermopile (Altp) Sensors Have Amentioning
confidence: 99%
“…All pressure measurements have an uncertainty of ±7%, as per Hayne et al [10]. [12], flush-mounted in cylindrical bodies of diameter 10.50 mm and corner radius 0.13 mm. This has an effective spherical radius of 15.21 mm.…”
Section: A T6 Stalker Tunnelmentioning
confidence: 99%
“…In-house signal conditioning units, L1TA3, which have a bandwidth of 400 Hz were used. The measured temperature is processed into heat flux using the Sequential Function Specification Method [12]. The overall uncertainty in the heat flux is 10%.…”
Section: A T6 Stalker Tunnelmentioning
confidence: 99%