2004
DOI: 10.1097/01.mat.0000132555.85820.8e
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Flexible Inflow Cannula With Titanium Inflow Tip for the NEDO Biventricular Assist Device

Abstract: A newly designed flexible inflow cannula has been developed for a biventricular assist device (BVAD). The inflow tip was designed for long-term ventricle drainage. Considering the anatomic differences between the right and left ventricles, a flexible inflow cannula, as a mass production model with a titanium tip, was developed and investigated in chronic BVAD animal experiments using the NEDO permanently implantable centrifugal blood pump. These flexible inflow cannulae consist of flexible plastic tubing with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Moving forward, additional studies relating the clinical occurrence of ventricular arrhythmias to molecular and physiological shifts within the myocardium will be invaluable in better defining which mechanisms are most strongly implicated in the time-dependent risks of ventricular arrhythmias in VAD-supported hearts. Further device evolution, including inflow cannula modifications [19,63] and inlet pressure control systems that adjust rotor speeds and prevent suction [23,[64][65][66], may reduce the incidence of ventricular arrhythmias among VAD-supported patients. Prospective trials assessing the benefits of de-novo prophylactic ICD placement and the need to replace ICDs in patients free of post-VAD ventricular arrhythmias would be particularly welcome.…”
Section: Resultsmentioning
confidence: 99%
“…Moving forward, additional studies relating the clinical occurrence of ventricular arrhythmias to molecular and physiological shifts within the myocardium will be invaluable in better defining which mechanisms are most strongly implicated in the time-dependent risks of ventricular arrhythmias in VAD-supported hearts. Further device evolution, including inflow cannula modifications [19,63] and inlet pressure control systems that adjust rotor speeds and prevent suction [23,[64][65][66], may reduce the incidence of ventricular arrhythmias among VAD-supported patients. Prospective trials assessing the benefits of de-novo prophylactic ICD placement and the need to replace ICDs in patients free of post-VAD ventricular arrhythmias would be particularly welcome.…”
Section: Resultsmentioning
confidence: 99%
“…This, in part, has served as a basis towards the development of ‘beak’, ‘corona’, and ‘trumpet’ designs with varied success due to thrombosis or thromboembolic complications related to insertion depth rather than inlet tip geometry. 2224 …”
Section: Discussionmentioning
confidence: 99%
“…[10] These remedies may however increase the possibility of thrombus formation due to flow disturbances causing shear activation of platelets and increased exposure time of stagnant blood to exposed myocardium at the apical wound site.…”
Section: Introductionmentioning