Abstract: This study presents a method of producing flexible electrodes for potentially simultaneously stimulating and measuring cellular signals in retinal cells. Currently, most multi-electrode applications rely primarily on etching, but the metals involved have a certain degree of brittleness, leaving them prone to cracking under prolonged pressure. This study proposes using silver chloride ink as a conductive metal, and polydimethysiloxane (PDMS) as the substrate to provide electrodes with an increased degree of fle… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 33 publications
0
9
0
Order By: Relevance
“…To calculate cathodal charge-storage capacity, the following formula was used [31]:CSCc=1vEcEajcudU, where CSC c is the cathodal charge-storage capacity mC/cm2, v is the sweep rate (mV/s), jcu is the cathodal current density false(mA/cm2), Ec and Ea are the cathodic and anodic extremes of the water window respectively, and U is the potential with respect to the RE (V). The calculation of tge cathodal charge-storage capacity was implemented in the above-mentioned software in OringPro.…”
Section: Methodsmentioning
confidence: 99%
“…To calculate cathodal charge-storage capacity, the following formula was used [31]:CSCc=1vEcEajcudU, where CSC c is the cathodal charge-storage capacity mC/cm2, v is the sweep rate (mV/s), jcu is the cathodal current density false(mA/cm2), Ec and Ea are the cathodic and anodic extremes of the water window respectively, and U is the potential with respect to the RE (V). The calculation of tge cathodal charge-storage capacity was implemented in the above-mentioned software in OringPro.…”
Section: Methodsmentioning
confidence: 99%
“…After evaluating available designs on the market and in the literature [ 30 ], a 3-electrodes system (working (WE), counter (CE) and reference (RE) electrodes), usually employed for electrochemical measurements, was selected as layout ( Figure 1 ).…”
Section: Methodsmentioning
confidence: 99%
“…However, to determine the solution resistance of a microelectrode whose roughness factor is not zero, it is necessary to calculate the equivalent electrical model of an electrode/electrolyte interface [24,25,26].…”
Section: Methodsmentioning
confidence: 99%
“…It is also possible to determine the cathodic charge storage capacity (CSC c ), which is defined as the total amount of reversible charge available in the cathodic phase of the stimulation pulse. It is calculated by integrating the cathodic current over a potential range whose limits correspond to the electrochemical potential window [24].…”
Section: Introductionmentioning
confidence: 99%