Development of a Generalized Scaled-Down Realistic Substation Laboratory Model for Smart Grid Research and Education

Abstract: This paper introduces a physical scaled-down realistic substation laboratory model development for translational research and education in smart grids. The development of a substation panel with four 3-φ feeders of 415 V, 65 A rating is described in detail. The developed substation model can be configured to realize seven widely used substation bus bar arrangements. A programmable logic controller (PLC) is used to create interlock mechanisms for mimicking the actual substation operation practices. Provision is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…Mehta et al developed special hardware for numerical overcurrent relay simulation [4], and the integrated complex distribution system was developed by Tang et al [5]. Guerrilla et al developed a miniature smart grid model used for research and education [6]. The difference with Idris & Partaker's research in feeder protection is by entering network parameters, and the difference with other laboratory developments is the application of technology.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Mehta et al developed special hardware for numerical overcurrent relay simulation [4], and the integrated complex distribution system was developed by Tang et al [5]. Guerrilla et al developed a miniature smart grid model used for research and education [6]. The difference with Idris & Partaker's research in feeder protection is by entering network parameters, and the difference with other laboratory developments is the application of technology.…”
Section: Literature Reviewmentioning
confidence: 99%
“…In consideration of personal safety, the local operation is strictly prohibited when the switch is stopped and powered on. The remote control operation includes the remote control operation of the switch by the dispatching control center through the dispatching data network and by the monitoring background computer in the substation [1][2][3].…”
Section: Introductionmentioning