2003
DOI: 10.1109/tns.2002.807869
|View full text |Cite
|
Sign up to set email alerts
|

Development of a GSO detector assembly for a continuous blood sampling system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
28
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 51 publications
(29 citation statements)
references
References 4 publications
1
28
0
Order By: Relevance
“…The inhalation period was 1 min for each gas. Arterial blood was continuously withdrawn during this dynamic scan, and the radioactivity concentration of the blood in the catheter tube was monitored using a scintillator block detector system (BeCON; Molecular Imaging Lab Inc., Suita City, Japan) [11]. Arterial blood samples were also taken before and after the dynamic scan, and arterial oxygen content (PO 2 ) and arterial PCO 2 were measured.…”
Section: Methodsmentioning
confidence: 99%
“…The inhalation period was 1 min for each gas. Arterial blood was continuously withdrawn during this dynamic scan, and the radioactivity concentration of the blood in the catheter tube was monitored using a scintillator block detector system (BeCON; Molecular Imaging Lab Inc., Suita City, Japan) [11]. Arterial blood samples were also taken before and after the dynamic scan, and arterial oxygen content (PO 2 ) and arterial PCO 2 were measured.…”
Section: Methodsmentioning
confidence: 99%
“…Some groups have successfully implemented micro-blood sampling techniques to reduce the impact of these problems [2,3]. Blood counter systems have also been described for both humans and animals [4-8] which allow continuous counting in a flowing catheter to achieve high time resolution. Beta microprobe systems have also been used to continuously measure IF without the need for blood sampling, in humans, primates, and rodents [9-13].…”
Section: Introductionmentioning
confidence: 99%
“…Venous blood collected from each monkey was infused into the system and was circulated by a peristaltic pump at a flow rate of 100 mL/minute, with the introduction of 15 O 2 and/or C 15 O gases at ∼7,000 MBq/minute/500 mL into the artificial lung for 5 to 15 minutes, producing the 15 O 2 –Hb and C 15 O–Hb samples of ∼60 MBq/mL. A coincidence detector block containing a pair of GSO scintillator 13 was implemented to monitor the radioactivity in the circulating blood. The 15 O 2 –Hb and C 15 O–Hb samples were adjusted to contain radioactivity of ∼17 MBq in 0.4 mL at the time of injection into the ICA.…”
Section: Methodsmentioning
confidence: 99%