Development of a High-performance Dual-energy Chest Imaging System

Abstract: Rationale and Objectives-To assess the performance of a newly developed dual-energy (DE) chest radiography system in comparison to digital radiography (DR) in the detection and characterization of lung nodules.Materials and Methods-An experimental prototype has been developed for high-performance DE chest imaging with total dose equivalent to a single posterior-anterior DR image. Low-and highkVp projections were used to decompose DE soft-tissue and bone images. A cohort of 55 patients (31 male, 24 female, mean… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…Studies involved two types of tests, performed by expert radiologists: (i) diagnostic satisfaction rating [18], in which the ability to perform a given visualization task was assessed with respect to a single displayed image; and (ii) preference rating [19], in which the ability to perform a given task was assessed with respect to two images displayed side-by-side.…”
Section: Observer Studiesmentioning
confidence: 99%
“…Studies involved two types of tests, performed by expert radiologists: (i) diagnostic satisfaction rating [18], in which the ability to perform a given visualization task was assessed with respect to a single displayed image; and (ii) preference rating [19], in which the ability to perform a given task was assessed with respect to two images displayed side-by-side.…”
Section: Observer Studiesmentioning
confidence: 99%
“…The motivation for this work was not only to identify optimal decomposition parameters, but also to compare the performance of model and human observers as these parameters are varied. Therefore, a nominal set of decomposition parameters ͑listed in Table II͒ was selected based on qualitative examination of patient im- ages acquired in an ongoing clinical study 43 such that the decomposed image provided adequate tissue cancellation and reduction of noise without introducing significant artifacts. 15 The nominal parameters were judged appropriate to diagnostic image quality by an expert chest radiologist.…”
Section: Iiib3 Dependence Of Performance On Decomposition Techniquementioning
confidence: 99%
“…Second, there is still a need for a simple algorithm to detect the bone and soft-tissue factors since the method proposed in [9][10][11] was too complex. Third, the runtimes for detecting the bone and soft-tissue factors and the entire DES process were long, i.e., 4 s for detecting the bone and soft-tissue factors [11], 10 s for the whole DES process [13], and the burden for radiologist workload by using the manual DES [12].…”
Section: Introductionmentioning
confidence: 99%