2018
DOI: 10.1186/s40543-018-0139-z
|View full text |Cite
|
Sign up to set email alerts
|

Development of a method for the determination of SCCPs (short-chain chlorinated paraffins) in bivalve mollusk using Soxtec device followed by gas chromatography-triple quadrupole tandem mass spectrometry

Abstract: Background: Organochlorinated compounds are major environmental concern due to their persistence, long-range transportability and bio-accumulation. Chlorinated paraffin (CP) mixtures, especially short-chain CPs (SCCPs), are found in environmental samples at very high levels. However, information about their levels is still insufficient, mainly in marine biota. Methods: This study aimed to optimize and validate a method for the determination of SCCPs (short-chain chlorinated paraffins) in bivalve mollusk using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…Nowadays, an improved method to perform Soxhlet extraction is named Soxtec [29]; this process is based on the same principles; however, thanks to pressure control, it is possible to accelerate the recirculation of the extractant solvent. In this way, the process is about 10 times faster [30].…”
Section: State Of the Art Of Solid-liquid Extraction Techniquesmentioning
confidence: 99%
“…Nowadays, an improved method to perform Soxhlet extraction is named Soxtec [29]; this process is based on the same principles; however, thanks to pressure control, it is possible to accelerate the recirculation of the extractant solvent. In this way, the process is about 10 times faster [30].…”
Section: State Of the Art Of Solid-liquid Extraction Techniquesmentioning
confidence: 99%
“…An aliquot of 10 mL was spiked with IS (20 ng) and dried with N 2 (30 °C). The sample was dissolved in n -hexane and added to a normal-phase chromatographic column containing activated silica (1.7 g), acidic silica (2.8 g, 40% sulfuric acid), and sodium sulfate . The column was washed with DCM (3 mL) and preconditioned with n -hexane (3 mL).…”
Section: Methodsmentioning
confidence: 99%
“…The sample was dissolved in n -hexane and added to a normal-phase chromatographic column containing activated silica (1.7 g), acidic silica (2.8 g, 40% sulfuric acid), and sodium sulfate. 26 The column was washed with DCM (3 mL) and preconditioned with n -hexane (3 mL). Two fractions were obtained after the column was rinsed with n -hexane (Fr.…”
Section: Methodsmentioning
confidence: 99%
“…The oven temperature program was 90 °C (1 min), 25 °C·min −1 to 150 °C and 8 °C·min −1 to 300 °C (15 min). Other measurement parameters of the instrument were provided in a recent publication 37 .…”
Section: Methodsmentioning
confidence: 99%