2010
DOI: 10.1002/jssc.201000013
|View full text |Cite
|
Sign up to set email alerts
|

Development of a molecularly imprinted polymer for selective extraction of bisphenol A in water samples

Abstract: A cross-linked methacrylate molecularly imprinted polymer (poly-4-vinylpyridine-co-trimethylolpropane-trimethacrylate) selective for bisphenol A (BPA) was synthesized, using a fluorinated BPA derivative (4,4'-(hexafluoroisopropylidene)-diphenol) as a mimic template, and applied to the analysis of real-world samples of process and potable waters. The molecularly imprinted polymer also showed a high affinity and selectivity for 17-beta-estradiol and ethynylestradiol. A method to analyze BPA, 17-beta-estradiol, a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(16 citation statements)
references
References 21 publications
0
16
0
Order By: Relevance
“…The efficiencies of MIP composites sensors prepared using dengue virus with BPA and without will be investigated in terms of substrate recognition. Available data on the use of MIPs based sensors to detect BPA has been used to compare to the results from this work . LOD by a virus assisted MCIP sensor determined here to detect BPA was lower than LOD from other MIPs based methods.…”
Section: Figurementioning
confidence: 55%
See 1 more Smart Citation
“…The efficiencies of MIP composites sensors prepared using dengue virus with BPA and without will be investigated in terms of substrate recognition. Available data on the use of MIPs based sensors to detect BPA has been used to compare to the results from this work . LOD by a virus assisted MCIP sensor determined here to detect BPA was lower than LOD from other MIPs based methods.…”
Section: Figurementioning
confidence: 55%
“…Available data on the use of MIPs based sensors to detect BPAh as been used to compare to the results from this work. [26][27][28] LOD by av irus assisted MCIP sensor determined here to detectB PA was lower than LOD from other MIPs based methods.…”
mentioning
confidence: 56%
“…Canale et al [82] packed BPA-MIPs into monolithic column and installed it on an HPLC unit for the determination of BPA in realworld water samples. The monolithic column exhibited good selectivity and concentration capability in the analysis of BPA in water samples.…”
Section: 113mentioning
confidence: 99%
“…Recently, endocrine disturbing chemicals have been identified as the most notorious contaminants (Canale et al, 2010;Jing et al, 2011;Cai et al, 2004). Recently, endocrine disturbing chemicals have been identified as the most notorious contaminants (Canale et al, 2010;Jing et al, 2011;Cai et al, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…There are several methods for sample preparation, such as microwave-assisted extraction (Pedersen and Lindholst, 1999), liquid-liquid extraction (LLE) (Helaleh et al, 2001), solid-phase microextraction (SPME) (Sanagi et al, 2015;Ali et al, 2008), liquid phase microextraction (LPME) (Basheer and Lee, 2004), molecularly imprinted solid-phase extraction (Canale et al, 2010;Ali, 2009), dispersive liquid-liquid microextraction (DLLME) (Rezaee et al, 2009) and solid-phase extraction (SPE). Among these methods, LLE is an exhaustive traditional preparation technique used to extract and preconcentrate different analytes from environmental water samples.…”
Section: Introductionmentioning
confidence: 99%