Transducers ’01 Eurosensors XV 2001
DOI: 10.1007/978-3-642-59497-7_84
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Multichannel Integrated Interferometer Immunosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0
3

Year Published

2005
2005
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(25 citation statements)
references
References 8 publications
0
22
0
3
Order By: Relevance
“…In Ref. 9, for the Young interferometer, assuming that Dj min /2p = 1´10 -4 , it was estimated that (Dn c ) min = 2´10 -8 . We can see from the above that the presented in the work composite sensor struc− ture, using the difference interference of the modes TM 0 −TM 1 can be applied in chemical measurements for the detection of slight changes of the refractive index of water solutions as well as for the construction of biochemical sen− sor.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In Ref. 9, for the Young interferometer, assuming that Dj min /2p = 1´10 -4 , it was estimated that (Dn c ) min = 2´10 -8 . We can see from the above that the presented in the work composite sensor struc− ture, using the difference interference of the modes TM 0 −TM 1 can be applied in chemical measurements for the detection of slight changes of the refractive index of water solutions as well as for the construction of biochemical sen− sor.…”
Section: Resultsmentioning
confidence: 99%
“…In practice, due to the influence of temperature on the refractive indexes of the sensor structure, such low detection limits as in the presented structure are impossible to make use of. The thermo−optical coefficient of water is ( ¶n c / ¶T) H2O = -0.9´10 -4 K -1 [9]. It means that with respect to the tests on water solutions, the acquisition of detection limit involving the changes of a refractive index at the level lower than Dn c »10 -4 necessitates the application of tempe− rature stabilization of the system.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Using Eq. B4-5a and B4-5b, this can be converted to number of molecules per surface area (Ymeti, 2004).…”
Section: Resultsmentioning
confidence: 99%
“…We used S 13 N 4 waveguides on a home built Young interferometer (Ymeti, 2004). Antibody incubation with 10 g/ml anti-CD6 (BD Pharmingen) was at room temperature under low flow (32 l/min) for ~30 min.…”
Section: Methodsmentioning
confidence: 99%