2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings 2012
DOI: 10.1109/i2mtc.2012.6229238
|View full text |Cite
|
Sign up to set email alerts
|

Development of a partial discharge emulator for calibration of a radiometric PD detection system

Abstract: A purely electronic partial discharge emulator for use in a location estimation algorithm for online partial discharge detection is proposed as a low-cost approach to real-time condition monitoring, asset management and operation optimization in future smart grid. Some early progress in the development of subsystems (specifically the radiometer antenna and PD emulator) for a proof-of-principle prototype system are described.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 6 publications
0
5
0
1
Order By: Relevance
“…O arranjo utilizado para as medições pode ser observado na Figura 2. O gerador de descarga parcial foi feita a partir de um cilindro de acrílico com dois eletrodos planos do tipo disco, em paralelo [10]. Dois parafusos de nylon são usados para definir a distância entre os elétrodos que estão ligados à fonte de alimentação de alta tensão.…”
Section: Modelo De Simulaçãounclassified
“…O arranjo utilizado para as medições pode ser observado na Figura 2. O gerador de descarga parcial foi feita a partir de um cilindro de acrílico com dois eletrodos planos do tipo disco, em paralelo [10]. Dois parafusos de nylon são usados para definir a distância entre os elétrodos que estão ligados à fonte de alimentação de alta tensão.…”
Section: Modelo De Simulaçãounclassified
“…It does not generate its signal using a discharge process and is not, therefore, subject to variation due to discharge damage of electrodes or insulation. The PD emulator is described in [4].…”
Section: B Pd Emulatormentioning
confidence: 99%
“…A more economical method of PD monitoring and location might be to employ PD intensity measurements followed by source location using, for example, path-loss law inversion [4]. Such measurements could be gathered using a broadband receiver as the sensing element at each node of a conventional wireless sensor network (WSN).…”
Section: Free-space Rf Measurements For Pd Source Locationmentioning
confidence: 99%