2022
DOI: 10.1007/s11094-022-02669-0
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Quantitative Determination Method for Aluminum Ions in Adsorbed Drugs Using Atomic Absorption Spectrometry with Electrothermal Atomization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…One spectroscopy method is electrothermal atomic absorption (EAA), an analytical technique determining the concentration of metallic elements in liquid samples 2 . Electrothermal atomization using a graphite tube furnace as an atomizer is a powerful and advantageous technique in atomic absorption spectroscopy because it allows analysis of refractory and trace analyte elements 3 , uses smaller samples, and provides higher sensitivity, making it a preferred choice in many analyses 4 .…”
Section: Introductionmentioning
confidence: 99%
“…One spectroscopy method is electrothermal atomic absorption (EAA), an analytical technique determining the concentration of metallic elements in liquid samples 2 . Electrothermal atomization using a graphite tube furnace as an atomizer is a powerful and advantageous technique in atomic absorption spectroscopy because it allows analysis of refractory and trace analyte elements 3 , uses smaller samples, and provides higher sensitivity, making it a preferred choice in many analyses 4 .…”
Section: Introductionmentioning
confidence: 99%
“…The consistency of atomization with F-AAS is not as good as using a graphite tube. [19] By using electrothermal atomization in terms of GF-AAS, these disadvantages mentioned for F-AAS can be circumvented. [20] To our knowledge, GF-AAS has not yet been evaluated for an Rb efflux assay.…”
Section: Introductionmentioning
confidence: 99%
“…A higher temperature of the flame may cause additional thermal excitation leading to ionization interference, while a decrease in temperature may be accompanied by insufficient atomization. The latter results in less sensitivity [ 14 ] and is generally valid for atoms analyzed using AAS. However, a comparison of atomization using a flame and graphite furnace when analyzing magnesium also showed a higher sensitivity for GF AAS [ 15 ].…”
Section: Introductionmentioning
confidence: 99%