2018
DOI: 10.1016/j.enzmictec.2017.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Development of an electrochemical immunosensor based on gold nanoparticles incorporated chitosan biopolymer nanocomposite film for the detection of prostate cancer using PSA as biomarker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
32
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 111 publications
(33 citation statements)
references
References 36 publications
1
32
0
Order By: Relevance
“…Incubation steps here were also consistent with conventional ELISA. Suresh et al modified the surface of a SPE using chitosan and gold nanoparticles (AuNPs) for the detection of PSA [ 141 ]. A sandwich immunoassay protocol was followed with HRP as the enzyme, but they amplified the signal using methylene blue as a redox mediator.…”
Section: Screen Printingmentioning
confidence: 99%
See 1 more Smart Citation
“…Incubation steps here were also consistent with conventional ELISA. Suresh et al modified the surface of a SPE using chitosan and gold nanoparticles (AuNPs) for the detection of PSA [ 141 ]. A sandwich immunoassay protocol was followed with HRP as the enzyme, but they amplified the signal using methylene blue as a redox mediator.…”
Section: Screen Printingmentioning
confidence: 99%
“…Electrochemical detection of PSA was monitored by cyclic voltammetry and square wave voltammetry. A dynamic range of 1–18 ng mL −1 was observed with LOD 1 pg mL −1 [ 141 ].…”
Section: Screen Printingmentioning
confidence: 99%
“…The food biosensor was still stable by the 20 th day retaining 96.3% of the initial current signal. The stability of the biosensor may be attributed to the utilization of CS and ABA [36,37]. To investigate the selectivity of the designed food biosensor, different food allergen proteins was tested (BSA, lysozyme, and casein).…”
Section: Reproducibility Stability and Selectivitymentioning
confidence: 99%
“…The immunosensor resulted in a highly selective and stable model, having a low PSA detection limit of 0.24 fg/mL [47]. Suresh et al (2018) applied an identical method, however, gold nanoparticles that were coated with a chitosan polymer were used to establish binding to the anti-PSA antibodies [48]. On the other hand, Vural et al (2018) proposed a method for PSA detection in blood serum samples that involved self-assembled AuNPs with peptide nanotube (PNT) and polyaniline (PANI) composites (PANI/AuNP–PNT) that were used to modify a pencil graphite electrode (PGE).…”
Section: Arena Of Gold Nanoparticles In Pcamentioning
confidence: 99%