2022
DOI: 10.1016/j.talanta.2022.123685
|View full text |Cite
|
Sign up to set email alerts
|

Development of an equipment free paper based fluorimetric method for the selective determination of histidine in human urine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
12
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 49 publications
0
12
0
Order By: Relevance
“…The main advantage of analytical paper devices is their portability in the field, and from our previous report [ 38 ], we have decided that the order of addition of the reagents is considered a key parameter to determine the manner and order of their deposition on the surface of the paper to manufacture suitable sensors for analytical determinations. It is a given that in all field analyses, the amount of analyte is added at the end of the experimental process, as all the reactants should be present and then the determination of the analyte be made.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The main advantage of analytical paper devices is their portability in the field, and from our previous report [ 38 ], we have decided that the order of addition of the reagents is considered a key parameter to determine the manner and order of their deposition on the surface of the paper to manufacture suitable sensors for analytical determinations. It is a given that in all field analyses, the amount of analyte is added at the end of the experimental process, as all the reactants should be present and then the determination of the analyte be made.…”
Section: Resultsmentioning
confidence: 99%
“…OPA is an established derivatization reagent for the fluorimetric determination of GSH [ 8 , 37 ]. Reduced GSH reacts with OPA to form a stable, highly fluorescent tricyclic derivate at pH 8, while other essential amino acids like L-histidine (His) react at a higher alkaline environment [ 38 ]. Additionally, paper-based analytical devices (PADs) have been developed in the past few years, at extremely fast rates, as alternative platforms for the determination of thiols based on their significant advantages, including low cost, portability, and minimal instrumentation demands [ 38 , 39 , 40 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this research work, the paper substrate was used for reagent storage and also volume limitation with the exploitation of hydrophobic barriers, and the signal has been acquired through the use of a conventional smartphone. 75 Another approach of a simple pattern fluorometric paper-based device exploits carbon dots (CDs) nanoparticles (NPs) properties with the platform's surface functionalization for folic acid detection in urine down to 0.28 μM as the detection limit (Figure 7B). The sustainable paper-based substrate that was used for the CDs fluorophore anchoring was attached on the PDMS plate providing an ultimate cost-effective hybrid sensing platform.…”
mentioning
confidence: 99%
“…Reprinted with permission from ref. []. Copyright 2019, Elsevier B.V. B) Fluorometric paper-based device exploiting carbon dot nanoparticles for folic acid detection.…”
mentioning
confidence: 99%