2018
DOI: 10.1016/j.jpba.2018.03.044
|View full text |Cite
|
Sign up to set email alerts
|

Development of an HPLC/UV method for the evaluation of extractables and leachables in plastic: Application to a plastic-packaged calcium gluconate glucoheptonate solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
2
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 13 publications
0
2
0
3
Order By: Relevance
“…Pequenas variações são impossíveis de serem excluídas dos testes estando presentes tanto na repetitividade quanto na reprodutibilidade, gerando os erros aleatórios (AGUIAR JÚNIOR et al, 2018). Como forma de relativizar essas divergências o parâmetro robustez mede a sensibilidade do método analítico frente a essas variações (LEGRAND et al, 2018).…”
Section: Validation Of Analytical Methods For Quantification Of Fipronunclassified
See 2 more Smart Citations
“…Pequenas variações são impossíveis de serem excluídas dos testes estando presentes tanto na repetitividade quanto na reprodutibilidade, gerando os erros aleatórios (AGUIAR JÚNIOR et al, 2018). Como forma de relativizar essas divergências o parâmetro robustez mede a sensibilidade do método analítico frente a essas variações (LEGRAND et al, 2018).…”
Section: Validation Of Analytical Methods For Quantification Of Fipronunclassified
“…O método cromatográfico depende também dos detectores, sendo os mais comuns o ultravioleta (UV), arranjo de fotodiodos e o espectrômetro de massas que quando associados à cromatografia formam um sistema analítico denominado hifenado (LEGRAND et al, 2018).…”
Section: Validation Of Analytical Methods For Quantification Of Fipronunclassified
See 1 more Smart Citation
“…High-performance liquid chromatography (HPLC) with ultraviolet (UV) detection or diode array detection (DAD) is the most commonly employed technique in the analysis of these additives. [9][10][11][12][13][14][15][16][17][18][19] The reversed-phase mode using octadecyl columns [10][11][12][13][14][20][21][22][23] and mixtures of acetonitrile/water or methanol/water as mobile phase 11,12,14,16,17,22 is by far the most commonly used chromatographic conditions currently for the analysis of these additives.…”
Section: Introductionmentioning
confidence: 99%
“…Many single-use plastics are manufactured from polypropylene and polyethylene. 5 Surgical masks, for example, are most commonly made of polypropylene (PP) polymer as it is cheap, easy to process, and possesses dielectric properties. 6 These masks, however, are difficult to recycle and are not biodegradable.…”
Section: Introductionmentioning
confidence: 99%