Development of an Immunofluorescence Assay Module for Determination of the Mycotoxin Zearalenone in Water

Abstract: Project Aquafluosense is designed to develop prototypes for a fluorescence-based instrumentation setup for in situ measurements of several characteristic parameters of water quality. In the scope of the project an enzyme-linked fluorescent immunoassay (ELFIA) method has been developed for the detection of several environmental xenobiotics, including mycotoxin zearalenone (ZON). ZON, produced by several plant pathogenic Fusarium species, has recently been identified as an emerging pollutant in surface water, pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 70 publications
0
11
0
1
Order By: Relevance
“…Furthermore, FCM provides an excellent interpretation of cellular processes such as redox balance, proliferation and apoptosis (Zhou et al, 2020;Broemsen et al, 2021). Whilst, microscopy, which is a rapid, cheap and simple technic, allows to investigate and examine histological changes on tissues induced by mycotoxins and through specific antibodies and fluorescence kits it enables to analyze their specific MOA (Nguyen et al, 2019;Gémes et al, 2021).…”
Section: Ochratoxinsmentioning
confidence: 99%
“…Furthermore, FCM provides an excellent interpretation of cellular processes such as redox balance, proliferation and apoptosis (Zhou et al, 2020;Broemsen et al, 2021). Whilst, microscopy, which is a rapid, cheap and simple technic, allows to investigate and examine histological changes on tissues induced by mycotoxins and through specific antibodies and fluorescence kits it enables to analyze their specific MOA (Nguyen et al, 2019;Gémes et al, 2021).…”
Section: Ochratoxinsmentioning
confidence: 99%
“…The scheme of this immunofluorescence module is shown in Figure 4 . The motor, optics and sample holder were developed at Optimal Optik Ltd. (Budapest, Hungary), while the detector electronics were created at the Budapest University of Technology and Economics (Budapest, Hungary) and described by Gémes et al [ 34 ]. Briefly, the samples were illuminated by an LED light source with a 520 to 535 nm minimum to maximum dominant wavelength range (Cree XPEBGR-L1-0000-00F01; Cree LED, Durham, NC, USA), and the emission was detected by a dichroic beam path with silicon photodiodes (PIN-25D, OSI Optoelectronics; Hawthorne, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The LOD of the method is 1.1 ng/mL, comparable to a laboratory-based enzyme-linked immunosorbent assay (ELISA) method with a LOD of 0.29–0.39 ng/mL. The development of a portable instrument for ZEN by enzyme-linked fluorescent immunoassay (ELFIA) is reported by Gémes et al [ 15 ], but as this instrument is a novel application for detection of mycotoxins as emerging water contaminants, it is discussed among the applications of routine monitoring (see Section 3 . Applications in routine monitoring).…”
Section: Methods Developmentmentioning
confidence: 99%
“…The occasional occurrence of mycotoxins in surface and drinking water is not a newly identified phenomenon, but its particular significance has been emphasized lately [ 7 , 8 , 22 , 24 , 25 , 26 ], classifying mycotoxins and their metabolites as emerging surface water contaminants [ 7 , 27 ], and assessing their routes of occurrence [ 28 , 29 ]. Gémes et al [ 15 ] report the development of an ELFIA method as a module of a portable, in situ fluorimeter instrument installed in a mobile laboratory vehicle to detect ZEN in water with a LOD of 0.09 ng/mL. This LOD appears to be quite favorable compared to reported ELISAs, but a major advantage of the ELFIA method lies in its combined in situ applicability in the determination of important water quality parameters detectable by induced fluorimetry—e.g., total organic carbon content, algal density or the level of other organic micropollutants.…”
Section: Applications In Routine Monitoringmentioning