“…The safeguard authorities requirement for 235 U abundance measurement uncertainty by TIMS is set to 0.28% [8]. The isotopic abundance of 234 U provides information about the type of activities conducted in the nuclear installations: enrichment or reprocessing [3,9]. However, 234 U stays a minor isotope with an isotopic abundance below 0.1% whatever its origins: enriched uranium, spent nuclear fuel, reprocessed uranium or depleted uranium.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The safeguard authorities requirement for 235 U abundance measurement uncertainty by TIMS is set to 0.28% [8]. The isotopic abundance of 234 U provides information about the type of activities conducted in the nuclear installations: enrichment or reprocessing [3,9]. However, 234 U stays a minor isotope with an isotopic abundance below 0.1% whatever its origins: enriched uranium, spent nuclear fuel, reprocessed uranium or depleted uranium.…”
Section: Introductionmentioning
confidence: 99%
“…The major development for the low quantities measurements is the use the electron multipliers [9,[13][14][15]18,19]. They are used to further extend the sensitivity of the instrument by several orders of magnitude.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Rhenium is the preferred material in these analyses for its high work function and melting point that is well above ionization temperatures for plutonium [3]. Rhenium also has been employed as an ionization surface for a variety of other analytes [4, 5, 6, 7, 8]. The use of rhenium in other high-temperature applications has been limited by its oxidation characteristics [9].…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8] The high precision of the isotope ratio measurements is ensured by utilizing state-of-the-art instruments, such as the thermal ionization mass spectrometer (TIMS) 2-4,7-14 and the multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS). [15][16][17][18] On the other hand, high precision itself does not necessarily guarantee that the measurement is accurate.…”
Section: Introductionmentioning