Development of an In Situ Analyzer Based on Sequential Injection Analysis and Liquid Waveguide Capillary Flow Cell for the Determination of Dissolved Reactive Phosphorus in Natural Waters

Abstract: This study presents an innovative technique for the in situ analysis of aquatic biochemical elements detected through wet chemical processes. A new compact in situ phosphate analyzer based on sequential injection analysis, liquid waveguide capillary flow cell and spectrophotometry was developed, and a safe and modular electronics-chemical separation mechanical structure was designed. The sequential injection system of this analyzer was optimized, and the major functions of this analyzer were studied and estima… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…Because of the superior metrology performance of reagent based analytical methods (Waterbury et al, 1996;Patey et al, 2008Patey et al, , 2010Ma et al, 2014a;Nagul et al, 2015;Birchill et al, 2019;Takeshita et al, 2020), numerous sensors and analytical systems have been developed employing these techniques. This includes in situ deployed systems for Nitrate (Jannasch et al, 1994;David et al, 1998;Steimle et al, 2002;Adornato et al, 2007;Vuillemin et al, 2009;Yaqoob et al, 2012;Bodini et al, 2015), Phosphate (Adornato et al, 2007;Barnard et al, 2009;Moscetta et al, 2009;Ma et al, 2014b;Bodini et al, 2015;Yang et al, 2020), Iron (Chapin et al, 2002;Johnson et al, 2007;Huang et al, 2012;Meyer et al, 2012), and pH (Waterbury et al, 1996;Bellerby et al, 2002;Martz et al, 2003;Liu et al, 2006;Nakano et al, 2006;Wang et al, 2007Wang et al, , 2015Seidel et al, 2008;Assmann et al, 2011;Spaulding et al, 2011;Lai et al, 2018). Some of these systems are commercially available (Hanson, 2000;Barnard et al, 2009;Spaulding et al, 2011;Bodini et al, 2015;…”
Section: Introductionmentioning
confidence: 99%
“…Because of the superior metrology performance of reagent based analytical methods (Waterbury et al, 1996;Patey et al, 2008Patey et al, , 2010Ma et al, 2014a;Nagul et al, 2015;Birchill et al, 2019;Takeshita et al, 2020), numerous sensors and analytical systems have been developed employing these techniques. This includes in situ deployed systems for Nitrate (Jannasch et al, 1994;David et al, 1998;Steimle et al, 2002;Adornato et al, 2007;Vuillemin et al, 2009;Yaqoob et al, 2012;Bodini et al, 2015), Phosphate (Adornato et al, 2007;Barnard et al, 2009;Moscetta et al, 2009;Ma et al, 2014b;Bodini et al, 2015;Yang et al, 2020), Iron (Chapin et al, 2002;Johnson et al, 2007;Huang et al, 2012;Meyer et al, 2012), and pH (Waterbury et al, 1996;Bellerby et al, 2002;Martz et al, 2003;Liu et al, 2006;Nakano et al, 2006;Wang et al, 2007Wang et al, , 2015Seidel et al, 2008;Assmann et al, 2011;Spaulding et al, 2011;Lai et al, 2018). Some of these systems are commercially available (Hanson, 2000;Barnard et al, 2009;Spaulding et al, 2011;Bodini et al, 2015;…”
Section: Introductionmentioning
confidence: 99%
“…The flow cell serves as a controlled environment where the sample interacts with reagents and undergoes various chemical reactions. 29,30 The single flow cell is used for all analyses. It is assumed that the entire sample drains out of the flow cell using a peristaltic pump.…”
mentioning
confidence: 99%