Development of an SDBC-MMCC-Based DSTATCOM for Real-Time Single-Phase Load Compensation in Three-Phase Power Distribution Systems

Abstract: This paper proposes a newly developed single-delta bridge-cell, modular multilevel cascade converter (SDBC-MMCC)-based distribution-level static synchronous compensator (DSTATCOM) for single-phase load compensation in three-phase, three-wire electric power distribution systems. Each main circuit arm of the DSTATCOM uses a modular multilevel cascade converter based on full-H-bridge (FHB) cells. The three main DSTATCOM arms are delta-connected to allow phase-independent operations for phase balancing and unity p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…Step V: 9.95 µF, 1.5 kvar, 2.2 A, 400 V The implemented MODBUS protocol was based on six callable functions, two of which were of particular interest: Function 03: "READ HOLDING REGISTERS" and Function 06: "PRESET SINGLE REGISTER", the first one for reading data and the second one for configuring the device for correction of the fault power [9,10].…”
Section: Power Factor Compensation Equipmentmentioning
confidence: 99%
See 2 more Smart Citations
“…Step V: 9.95 µF, 1.5 kvar, 2.2 A, 400 V The implemented MODBUS protocol was based on six callable functions, two of which were of particular interest: Function 03: "READ HOLDING REGISTERS" and Function 06: "PRESET SINGLE REGISTER", the first one for reading data and the second one for configuring the device for correction of the fault power [9,10].…”
Section: Power Factor Compensation Equipmentmentioning
confidence: 99%
“…Examples of addresses and what is read from them are given in Table 3. There are hundreds of addresses with possible readable values [9,10]. The device implementation monitors Line 1, but the commands are available for implementations with several devices.…”
Section: Power Factor Compensation Equipmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Similarly, a number of traditional solutions to (PQ) problems have been around for a long duration. However, these traditional methods rely on passive parts and do not always adapt appropriately to changes in the nature of a electrical power system [2].…”
Section: Introductionmentioning
confidence: 99%
“…In [15], the authors have proposed a D-STATCOM to compensate the unbalanced conditions resulting in dc voltage oscillation via PR control. A PID control is employed for SDBC-MMC to compensate the single-phase load in a power distribution system for power factor correction [16]. The authors in [17], have presented a cascaded multi-level inverter-based D-STATCOM during grid transients and load alterations via PI control for reactive power compensation.…”
mentioning
confidence: 99%