Abstract:Effective organ retraction is essential to ensure safe and efficient surgery, in the case of laparoscopic surgery, organ retraction is particularly difficult to achieve. Currently such as cherry dissectors are used for retraction, however the small size results in excessive stress on the organ being retracted. Therefore, we are developing a balloon-based retractor that provides similar functionality as the cherry dissector, particularly being able to pass through a small port, yet being expandable to provide a… Show more
“…Additionally, the nylon mesh covering provides the frictional coefficient of retraction required to ensure effective and appropriate stabilization of the lung. 7…”
Section: Discussionmentioning
confidence: 99%
“…There are some other commercially available surgical devices that use the same concept of enlarging the working contact surface area for endoscopic surgery 7,16 ; however, there is little literature outlining the benefits of such devices. A high frictional coefficient of the retractor surface is integral in providing effective and appropriate control of such slippery organs.…”
Section: Discussionmentioning
confidence: 99%
“…We have detailed the high frictional coefficient provided by this retractor in comparison with existing retractors in a previous study. 7 One of the most important advantages of our current balloon-based retractor is that the entire circumferential area of the retractor makes contact with the organ, including the side wall as well as the tip. This is the main reason that we selected the balloon-based mechanism for our retractor.…”
Section: Discussionmentioning
confidence: 99%
“…2-6 We have previously reported the development of this balloon-based organ retractor and its effective frictional coefficient of retraction. 7 The aim of this study was to evaluate the effectiveness of the balloon-based retractor in the dry and wet labs.…”
“…Additionally, the nylon mesh covering provides the frictional coefficient of retraction required to ensure effective and appropriate stabilization of the lung. 7…”
Section: Discussionmentioning
confidence: 99%
“…There are some other commercially available surgical devices that use the same concept of enlarging the working contact surface area for endoscopic surgery 7,16 ; however, there is little literature outlining the benefits of such devices. A high frictional coefficient of the retractor surface is integral in providing effective and appropriate control of such slippery organs.…”
Section: Discussionmentioning
confidence: 99%
“…We have detailed the high frictional coefficient provided by this retractor in comparison with existing retractors in a previous study. 7 One of the most important advantages of our current balloon-based retractor is that the entire circumferential area of the retractor makes contact with the organ, including the side wall as well as the tip. This is the main reason that we selected the balloon-based mechanism for our retractor.…”
Section: Discussionmentioning
confidence: 99%
“…2-6 We have previously reported the development of this balloon-based organ retractor and its effective frictional coefficient of retraction. 7 The aim of this study was to evaluate the effectiveness of the balloon-based retractor in the dry and wet labs.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.