2017
DOI: 10.1002/ecj.12021
|View full text |Cite
|
Sign up to set email alerts
|

Development of Biosignal Recording Board System with Agile Control of Circuit Characteristics for Various Biosignals

Abstract: Recently, a novel recording system is strongly required for agile and precise recording of biosignals in various fields, such as medicine, neuroscience, BMI (brain machine interface), and so on. To enable such various biosignal recording, we have proposed an agile biosignal recording system with a newly designed analog front-end LSI chip having amplification, filtering, and A/D conversion functions. In this paper, we designed and evaluated a neural signal recording circuit and a portable front-end motherboard.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…Figure 5A illustrates the bandwidth of an Ag/AgCl-gated p(g 3 C 2 T2-T) OECT, with an f c of 8.1 Hz in PBS and 234 Hz in IL. Since the effective frequency range of ECG is from 0.05 to 100 Hz, 34 the IL-gated OECT's bandwidth would retain all the signal components without loss. To verify this hypothesis, we connected an ECG simulator between the gate and the source of the OECT and monitored the I D in the presence of either electrolyte (Figure 5B).…”
Section: Since [Emim]mentioning
confidence: 99%
“…Figure 5A illustrates the bandwidth of an Ag/AgCl-gated p(g 3 C 2 T2-T) OECT, with an f c of 8.1 Hz in PBS and 234 Hz in IL. Since the effective frequency range of ECG is from 0.05 to 100 Hz, 34 the IL-gated OECT's bandwidth would retain all the signal components without loss. To verify this hypothesis, we connected an ECG simulator between the gate and the source of the OECT and monitored the I D in the presence of either electrolyte (Figure 5B).…”
Section: Since [Emim]mentioning
confidence: 99%
“…Brain signals such as electroencephalography (EEG) and electrocorticography (ECoG) are used to diagnose epilepsy and have a very low amplitude between 1 μV and 5 mV. Other biological signals like ECG and electromyography have an amplitude that ranges from 100 μV to 5 mV . These waveforms need amplification before being processed by an analogue digital converter (ADC).…”
Section: Introductionmentioning
confidence: 99%